EASY MENU DRIVEN PROGRAM MODE
EASY MENU DRIVEN PROGRAM MODE
DEALER PROGRAM - PRELIMINARY INFORMATION
Only Keypad #1 may be used for both dealer and user programming, however this keypad may be located in any area.
The Master Security Code is printed on the panel’s microprocessor can. Use this code to enter the Dealer Program Mode
to program a custom Dealer Security Code. Record the number, then remove the code label to prevent unauthorized
access to the panel. If you forget your Dealer Security Code, use the Master Security Code to enter programming.
After entering codes or data, press the save U button. Data will not be stored into memory unless it is pressed.
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
Silence the sounder by pressing the G button to continue, or by pressing the C button to exit.
A panel that has been COLD STARTED (Address Location 4093) performs identically to a new panel.
If a GEM-RP2ASe2/GEM-K2AS (Version 6) is used, configure address jumpers as Keypad #1 (see WI1184).
KEYPAD #1: For ease of programming, it is recommended that a GEM-K1CA (Version 8) be used as Keypad #1.
(Regardless of which keypad is selected, all new keypads are configured as Keypad #1 out of the box).
NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any
means, the number of areas, number of zones, fire zones, entry/exit zones and interior zones will be suppressed and cannot be
changed. Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the
C
button to enter the Direct Address Program Mode; (b) access Location 4091 (Clear Program); (c) press the
U button and start over.
1. Press EEEEEE R
2. Press Q Until “ACTIVATE PROGRAM Y/N” appears on the keypad display.
3. Press P To Enter Dealer Program Mode.
4. Press CC To Exit Dealer Program Mode when finished.
Master Security Code
(on microshield)
R
GEM-P3200
CONTROL
COMMUNCIATOR
MASTER SECURITY CODE
# - # - # - # - # - #
ACCESSING DEALER PROGRAM MODE
CUSTOMIZING A DEFAULT PROGRAM
For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:
This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has been
loaded, you may alter it as necessary in the Direct Address Program Mode.
Total Number of Zones in Area 1
Total Number of Zones in Area 2
Fire Zones in Area 1
2-Wire Fire Zones in Area 1
Report All Zones to Central
Exit/Entry Zones in Area 1
Interior Zones in Area 1
24 Hour Zones in Area 1
Chime Zones in Area 1
Chime 2 Zones in Area 1
Exit/Entry2 Zones in Area 1
50mS Loop Response Zones (Note: 750mS is
required for Loop Response time in UL installations).
Aux Output Activated on Alarm Zones
Sensor Watch Zones
Keypad Sounder on Alarm Zones
Auto Bypass re-entry Zones
Enable no EOLR Zones
Enable Telco Line Fault Test
Enable Burg Output Chirp on Keyfob
Enable SIA CP-01 Features
Number of Keypads in Area 1
Number of Keypads in Area 2
Central Station Receiver 1 Tel. Number
Central Station Receiver 1 Account Number
Central Station Receiver 1 Format
Enter User Codes
RF Transmitter Points
Quick Method (Enroll Method)
KeyFob Transmitters (as Arm/Disarm & Control
Devices)
KeyFob Transmitters (as Zone Input Devices)
Enter Zone Descriptions
Enter Date
Enter Time
Dealer Code
Exit Dealer Program Mode