Mitsubishi Electronics Q172DCPU Home Security System User Manual


 
3 - 21
3 COMMON PARAMETERS
(3) Extension setting parameters
No. Symbol Name Initial value Unit
PC01 ERZ Error excessive alarm level 3 rev
PC02 MBR Electromagnetic brake sequence output 0 ms
PC03 ENRS Encoder output pulse selection 0000h
PC04 COP1 Function selection C-1 0000h
PC05 COP2 Function selection C-2 0000h
PC06 COP3 Function selection C-3 0000h
PC07 ZSP Zero speed 50 r/min
PC08 For manufacturer setting 0
PC09 MOD1 Analog monitor 1 output 0000h
PC10 MOD2 Analog monitor 2 output 0001h
PC11 MO1 Analog monitor 1 offset 0 mV
PC12 MO2 Analog monitor 2 offset 0 mV
PC13 MOSDL Analog monitor feedback position output standard data Low 0 PLS
PC14 MOSDH Analog monitor feedback position output standard data High 0 10000PLS
PC15 0
PC16
For manufacturer setting
0000h
PC17 COP4 Function selection C-4 0000h
PC18 0000h
PC19 0000h
PC20
For manufacturer setting
0000h
PC21 BPS Alarm history clear 0000h
PC22 0000h
PC23 0000h
PC24 0000h
PC25 0000h
PC26 0000h
PC27 0000h
PC28 0000h
PC29 0000h
PC30 0000h
PC31 0000h
PC32
For manufacturer setting
0000h
POINTS
(1) When the items marked " " in the above table has changed, make the Multiple
CPU system reset or power supply OFF to ON. And, once turn OFF the servo
amplifier power supply and then turn ON it again.