Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV:
SHEET 250
Table 5.3.9-5: Navigation Inputs Select 5
SIGNAL CONNECTION REFERENCE SUMMARY DATA
Glideslope Deviation
(+) = J1-65
(-) = J1-46
6.1.6
4.2.3.2
Format: ARINC 547 with Validity Flag & ILS Select
Input Type: Basic
Fault Designation: GLIDESLOPE FAULT
Validity: Glideslope Validity Discrete #1 (+28V)
Localizer Deviation
(+) = J1-30
(-) = J1-10
6.1.17
4.2.3.3
Format: ARINC 547 with Validity Flag & ILS Select
Input Type: Basic
Fault Designation: LOCALIZER FAULT
Validity: Glideslope Validity Discrete #1 (+28V)
PIN FUNCTION
CONNECTION PIN TYPE
CHANNEL DESIGNATION
REFERENCE
Polarity/Configuration Reference
Localizer Validity
Discrete #1
J1-48 Input 28V_DISC_11 >+17V = Valid
< +4.4V = Not Valid
6.6.28
4.2.7
Glideslope Validity
Discrete #1
J1-11 Input 28V_DISC_06 >+17V = Valid
< +4.4V = Not Valid
6.6.10
4.2.7
+28V ILS Tuned
Discrete #1
J1-39 Input 28V_DISC_01 >+17V = ILS Tuned
< +4.4V = ILS Not Tuned
6.6.9
4.2.7
GND ILS Tuned
Discrete #1
J1-20 Input GND_DISC_01 Gnd = ILS Tuned
<not> Gnd = ILS Not Tuned
6.6.8
4.2.7
Table 5.3.9-250: Navigation Inputs Select 250
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Glideslope
Localizer
PFD Mode Select Word
Selected Course
Reference
6.2.30
6.2.33
6.2.44
6.2.61
Label
174
173
163
100
Sig. Bits
12
12
Discrete
11
Range
±0.8 DDM
±0.4 DDM
Type 4
±180 degrees
Signal Type
Basic
Basic
Basic
Basic
Resolution
0.0001953125
0.00009765625
n/a
0.087890625
Rate (ms)
33.3-66.6
33.3-66.6
250
200
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Glideslope
Localizer
PFD Mode Select Word
Selected Course
Reference
6.2.30
6.2.33
6.2.44
6.2.61
Label
174
173
163
100
Sig. Bits
12
12
Discrete
11
Range
±0.8 DDM
±0.4 DDM
Type 4
±180 degrees
Signal Type
Basic
Basic
Basic
Basic
Resolution
0.0001953125
0.00009765625
n/a
0.087890625
Rate (ms)
33.3-66.6
33.3-66.6
250
200
Table 5.3.9-251: Navigation Inputs Select 251
CHANNEL
429/422RX_1
CONNECT TO: IOC #1
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Glideslope
Localizer
Selected Course
Reference
6.2.30
6.2.33
6.2.61
Label
174
173
100
Sig. Bits
12
12
11
Range
±0.8 DDM
±0.4 DDM
±180 degrees
Signal Type
Basic
Basic
Basic
Resolution
0.0001953125
0.00009765625
0.087890625
Rate (ms)
33.3-100
33.3-100
33.3-100
CHANNEL
429RX_3
CONNECT TO: IOC #2
Format: ARINC 429 (High Speed)
Fault Designation: IOC BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Glideslope
Localizer
Selected Course
Reference
6.2.30
6.2.33
6.2.61
Label
174
173
100
Sig. Bits
12
12
11
Range
±0.8 DDM
±0.4 DDM
±180 degrees
Signal Type
Basic
Basic
Basic
Resolution
0.0001953125
0.00009765625
0.087890625
Rate (ms)
33.3-100
33.3-100
33.3-100