Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV:
SHEET 227
Table 5.3.6.1-245 Honeywell SPZ8000, EDZ806, (Integrated) with dual SCI range MK VIII Only
Display Configuration Group 250
Function Value Reference section
Display Type Honeywell (SPZ8000 new style) every fourth display line is blanked
Sweep Type Honeywell
Category 7, Options Select Group #1
TA&D Alternate Pop Up: False TA&D Alternate Pop Up: True
Auto Pop Up
Pop Up On Caution or Warning Never Pop Up
5.3.7
Category 7, Options Select Group #1
Peaks Enable: False Peaks Enable: True
Peaks Mode
Peaks Off Peaks On
5.3.7
Manual select Selection is controlled by display
Manual deselect Deselection is controlled by display
Auto Range Yes 10NM
Moving Marker Yes (Honeywell type)
Overlay Page Yes for Peaks Elevations only (located middle right of display)
Display bus type Honeywell picture bus
DISPLAY BUS #1
453TX_1
CONNECT TO:
A = J1-58
B = J1-59
Terrain Display data to switching relay/Symbol Generator #1 and MFD left channel 4.2.13.2
7.2
DISPLAY BUS #2
453TX_2
CONNECT TO:
A = J1-56
B = J1-57
Terrain Display data to switching relay/Symbol Generator #1 and MFD right channel 4.2.13.2
7.2
Display Input Control Group 249
CHANNEL
429_422RX_1
CONNECT TO: SCI Bus 1
Format: RS-422 (12.0K baud)
Fault Designation: DISPLAY BUS 1
Bus Type: Basic
A = J2-36
B = J2-37
Data
Range (Mode/Range word)
Status
Reference
6.5.1.1
6.5.1.2
Label
80
FF
Sig. Bits
4 discrete
Discrete
Range
2000NM
N/A
Signal Type
Basic
Basic
Resolution
N/A
N/A
Rate (ms)
100
100
CHANNEL
429RX_3
CONNECT TO: SCI Bus 2
Format: RS-422 (12.0K baud)
Fault Designation: DISPLAY BUS 2
Bus Type: Basic
A = J2-10
B = J2-11
Data
Range (Mode/Range word)
Status
Reference
6.5.1.1
6.5.1.2
Label
80
FF
Sig. Bits
4 discrete
Discrete
Range
2000NM
N/A
Signal Type
Basic
Basic
Resolution
N/A
N/A
Rate (ms)
100
100
Output 429 Bus Group 0
Channel Pins Comments
429TX_1 (Low Speed) A = J2-43
B = J2-42
Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x, and 7.1.4.x
Integration Notes:
1. The EGPWS ARINC 429 Output Bus must be connected to the display.
2. The ‘DISPLAY BUS’ fault will be present only if both MG inputs have failed.
3. The Honeywell EFIS SG & MG provide Terrain display relay control.
4. When interfacing to a single display controller configuration the bus must be connected to both EGPWS input
channels. This prevents the EGPWS from reporting an external bus fault on the second channel.
5. The display uses the following ARINC 429 labels from the EGPWS for annunciations. The Terrain display will
annunciate: “TERR” in green or cyan (depending on the program) when the Terrain is selected and valid.
“TERR” in amber if Terrain is selected and any of the following conditions are TRUE:
The EGPWS ARINC 429 output bus is missing or labels 050 and 051 are absent or unreadable for 2 seconds.
EGPWS ARINC label 051 bit 13 = 0 (“Terrain Display Valid” bit FALSE).
EGPWS ARINC label 050 bit 17 = 1 (“Terrain Inhibit” bit TRUE).
EGPWS ARINC labels are valid, but the range in label 050 disagrees with the range via SCI bus label 80 (label
050 bit 11-14 contain left display bus range and bits 15-18 are the right display bus range).
The display will be blanked when the amber “TERR” is present.
The display will Pop Up to Terrain mode as follows: