Honeywell MK VI Home Security System User Manual


 
Honeywell
MK VI MK VIII EGPWS Installation Design Guide
Proprietary notice on title page applies
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-150 REV:
SHEET 176
Step
(Category)
Signal Selection Instruction
Ident No.
13
Selects:
a) Input Discrete
Functions
b) Output Discrete
Functions
Using Table 5.3.13, and any sub-tables
contained within, locate the desired I / O
Discrete type.
Record the Ident (ID No.) on the space
available on Ident column of this table.
_______
ID #
14
Selects:
a) Audio Output Level
Using Table 5.3.14, and any sub-tables
contained within, locate the desired Volume
type.
Record the Ident (ID No.) on the space
available on Ident column of this table.
_______
ID #
15
Selects:
a) Unused
Using Table 5.3.15, select “0” Unused.
Record the Ident “0” (ID No.) on the
space available on Ident column of this
table.
__
0
__
ID #
16
Selects:
b) Unused
Using Table 5.3.16, select “0” Unused.
Record the Ident “0” (ID No.) on the
space available on Ident column of this
table.
__
0
__
ID #
17
Selects:
c) Unused
Using Table 5.3.17, select “0” Unused.
Record the Ident “0” (ID No.) on the
space available on Ident column of this
table.
__
0
__
ID #
LIMITATIONS: The described use of the configuration module provides for maximum flexibility in selection of input
sensors and output behavior. Every attempt has been made to avoid conflicts arising between categories and to reflect the
known configurations of aircraft. However in the case of input sensors it should not be construed that all combinations are
valid configurations. There may be configurations not supported by the EGPWS software configuration building process
(which will cause the EGPWS to fail in an obvious manner). In general you can not have redundancy through the mixing
of analog and digital sources, however redundant digital signals on different buses are permissable. As it is not practical to
verify all possible sensor combinations, verification of particular sensor combinations is part of the installation
certification process. If you intend to implement a sensor configuration not currently identified in Section 5, please contact
Honeywell or an authorized dealer/installer.