Honeywell 3.5 Home Security System User Manual


 
VISTA-40 Installation and Setup Guide
5-12
FIELD
TITLE and DATA ENTRIES EXPLANATION
2*02
Daylight Saving Time Start/End
Weekend
0 = disable
1 = enable
Enter the start and end weekends for daylight saving time as follows:
1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from
last. Standard setting for U.S. is 1,5.
2*17
Number of Codes per Partition
Enter 01-69
This field has two 2-digit entries. Enter the number user codes for each
partition. The total number of user codes cannot exceed 70 for the system.
Enter 01 for an unused partition.
NOTE: The installer code is automatically assigned to each partition
regardless of whether that partition has been enabled.
2*18
Enable GOTO for this Partition
(partition-specific)
0 = disable
1 = enable
If enabled, this partition can be accessed from another partitions keypad
using the GOTO command.
2*19
Use Partition Descriptor
0 = disable
1 = enable
If enabled, the normal keypad display will include a partition number and
four-digit descriptor.
2*20
Enable J7 Triggers for Partition
(partition-specific)
0 = disable
1 = enable
If enabled, the J7 triggers function for this partition.
2*21
Supervision Pulses for LRR
0 = disable
1 = enable
There are three entries in this field as follows: Fire, Burglary/Audible
Panic, Silent Panic/Duress.
If enabled, causes the control to send periodic short pulses on the J7 radio
triggers to the LRR. The LRR uses these pulses to determine that its
connection to the control is still intact.
Must be 1 for UL installations.