Honeywell 3.5 Home Security System User Manual


 
5-1
SECTION 5
Data Field Descriptions
•••••••••••••••••••••••••••••••••••••••••••••••••
About Data Field Programming
The following pages list this controls data fields in numerical order. Field numbers are listed in the left column, followed
by a Title and Data Entries column, which lists the valid entries for each field. Experienced installers can simply follow
this column when programming the data fields. The Explanation column provides explanatory information and special
notes where applicable.
NOTE: Refer to the Programming Guide for the default values. They are not listed in this section.
Use the Programming Guide to record the data for this installation.
Programming Data Fields
Data field programming involves making the appropriate entries for each of the data fields. Start Data Field
programming by entering the installer code + 8 + 0 + 0.
FIELD
TITLE and DATA ENTRIES EXPLANATION
*00
Installer Code
Enter 4 digits, 0-9
The Installer Code is a 4-digit code reserved for installation company use.
This is the only code that can be used to enter the Program Mode from
the keypad. This code cannot be used to disarm the system if it isnt used
to arm the system. This code cannot be used to re-enter Program Mode if
Program Mode is exited by the *98 command.
*02
Response Types for Zones 0108
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
*03
Response Types for Zones 0916
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
*04
Response Types for Zones 1724
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
*05
Response Types for Zones 25
27, 97, 95, 96, and 99
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
*09
Entry Delay #1 (partition-specific)
Enter 02-15 multiplied by 15 seconds.
00 = no delay.
Entry delay defines the delay time that allows users to re-enter the
premises through a door that has been programmed as an entry delay
door and disarm the system without sounding an alarm. The system must
be disarmed within this period or an alarm will occur.
NOTE: The delay may not exceed 45 seconds for UL installations.
*10
Exit Delay #1 (partition-specific)
Enter 03-15 multiplied by 15 seconds.
00 = no delay.
Exit delay defines the delay period that allows users to leave the premises
through a door that has been programmed as an entry/exit delay door
after arming the system without setting off the alarm.
*11
Entry Delay #2 (partition-specific)
Enter 02-15 multiplied by 15 seconds.
00 = no delay.
Entry Delay #2 is used for a secondary door requiring a longer delay than
those assigned to Entry Delay #1.
NOTE: The delay may not exceed 45 seconds for UL installations.