Honeywell 3.5 Home Security System User Manual


 
Section 5 Data Field Descriptions
5-11
FIELD
TITLE and DATA ENTRIES EXPLANATION
1*49
Suppress Transmitter
Supervision Sound
0 = disable
1 = enable
If enabled, no trouble soundings occur on the keypad for transmitter
check-in failures.
Must be 0 for UL.
1*52
Send Cancel If Alarm + Off
(partition-specific)
0 = disable
1 = enable
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTE: This option must be enabled so Cancel reports are always sent.
1*53
Disable Download Callback
0 = callback required
1 = no callback required
Select whether a callback from the control panel is required for
downloading.
Must be 0 for UL installations.
1*57
Enable 5800 RF Button Global
Arm
0 = disable
1 = enable
If enabled, the system arms/disarms in accordance with the buttons
users global arming settings.
1*58
Enable 5800 RF Button Force
Arm
0 = disable
1 = enable
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE: When attempting to arm the system, the keypad beeps once after
the button is pressed if any faulted zones are present. The user should
then press the button again within 4 seconds to force-bypass those zones
and arm the system.
1*60
Zone 5 Audio Alarm Verification
0 = disable
1 = enable
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
NOTE: Zone 5 cannot be used as protection zone.
1*70
Event Log Types
0 = disable
1 = enable
This field has five entries as follows: Alarm, Check, Bypass, Open/Close,
and System. If enabled, the system logs those events into the event log.
1*71
12/24 Hour Type Stamp Format
0 = 12-hour
1 = 24-hour
Select the type of time stamping for the event log.
1*74
Relay Timeout XXX Minutes
Enter 000-127 times 2 minutes (000-254).
This is used for Relay Programming in the #93 Menu Mode Programming
relay command 56.
1*75
Relay Timeout YYY Seconds
Enter 000-127 seconds.
This is used for Relay Programming in the #93 Menu Mode Programming
command 57.
1*76
Access Control Relay (partition-
specific)
01-08 = relay number
00 = relay not used.
If enabled, the assigned relay closes for 2 seconds when the user enters
his code and presses 0.
Must be 00 for UL installations.
2*00
Number of Partitions
Enter 1-2.
Enter the number of partitions used in the system.
2*01
Daylight Saving Time Start/End
Month
0 = disable
1 = enable
Enter the months (00-12) in which daylight saving time starts and ends.
Enter 00, 00 if daylight saving time does not apply to the users region.
Standard setting for U.S. is 04,10.