Section 3 - Installing the Control
3-23
RED
GREEN
RING
TIP
NOT USED
EARTH GND
GND
AUXILIARY AUD ENABLE
AUXILIARY AUD IN
SPKR 7
SPKR 6
SPKR 5
SPKR 4
SPKR 3
SPKR 2
SPKR 1
GND
GND
+12VDC IN
GND
INSIDE UVST PWR
INSIDE UVST PWR
OUTSIDE UVST PWR
ALARM TRIG IN
VOICE RELAY POLE
VOICE RELAY NC
FALLING VOICE TRIG
RISING VOICE TRIG
NOT USED
MIC 7
MIC 6
MIC 5
MIC 4
MIC 3
MIC 2
MIC 1
SWITCH BANK 1 SWITCH BANK 2
SW SWITCH BANK 1
1 UVST 1 AUX AUDIO, ON = ENABLED
2 UVST 2 AUX AUDIO, ON = ENABLED
3 UVST 3 AUX AUDIO, ON = ENABLED
4 UVST 4 AUX AUDIO, ON = ENABLED
5 UVST 5 AUX AUDIO, ON = ENABLED
6 UVST 6, ON = OUTSIDE, OFF = INSIDE
7 UVST 7, ON = OUTSIDE, OFF = INSIDE
8 VOICE TRIGGER, ON = IMMED, OFF = CALLBACK
SW SWITCH BANK 2
1 FUTURE USE, SET TO ON
2 FUTURE USE, SET TO ON
3 TELEPHONE RING, ON = ENABLED
4 END USER VOICE, ON = DISABLED
5 FUTURE USE, SET TO ON
6 CS CODE LEARN, ON = DISABLED
7 USER CODE LEARN, ON = DISABLED
8 FUTURE USE, SET TO ON
SHIPPED WITH ALL SWITCHES IN "ON" POSITION.
ON ON
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
INCOMING RING
INCOMING TIP
HANDSET RING
HANDSET TIP
CONTROL PANEL
BELL OUTPUT
GND
AUX PWR (12VDC)
2-WAY VOICE TRIGGER
(SEE NOTE 3)
(OPTIONAL; NOTE 5)
(NOTE 2)
(NOTE 2)
4286 VIP
MODULE
1234567
1234
KEYED
HEADER
SPEAKER
VOLUME
CONTROL
OPTIONAL
(NOTE 4)
UVST PWR
GND
MIC
SPKR
SPEAKER
VOLUME
TRIM POT
TYPICAL 1 OF 7
AUDIO OUT
GND
MUSIC SOURCE
OPTIONAL
(NOTE 4)
PREMISES
ANSWERING
MACHINE AND
PHONE (S)
ANSWERING
MACHINE
P3
UVST
VOLUME CONTROL DIAL
TIP
RING
TIP
RING
12345678 12345678
NOTE 1: CONNECT TO PROPER EARTH GROUND.
NOTE 2:
POWER MAY ALSO BE SUPPLIED BY A LISTED CLASS 2
POWER SUPPLY RATED 12VDC, MIN 600mA CONNECTED TO THE
UVCM +12VDC IN AND GND TERMINALS.
NOTE 3:
SOME CONTROL PANELS USE BUILT-IN TRIGGER AND SOME
USE 4204 RELAY MODULE. REFER TO AAV SECTION OF CONTROL PANEL
INSTALLATION AND SETUP GUIDE FOR CONNECTION.
NOTE 4: EITHER MUSIC SOURCE OR 4286 VIP MODULE CAN BE USED BUT
NOT AT THE SAME TIME.
NOTE 5: DO NOT CONNECT IF 4286 VIP MODULE IS USED.
1 2 3 4 5 6 7 8 910111213
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
SELECT
APPROPRIATE
INPUT
RJ31X
JACK
PLUG
DIRECT
CONNECT
CORD
NOTE 1
UVCM AND UVST SUMMARY OF CONNECTIONS
P2
P1
P7
FOR COMPLETE INFORMATION, SEE
4286 VIP MODULE INSTRUCTIONS.
WARNING: TO PREVENT RISK
OF ELECTRICAL SHOCK,
DISCONNECT TELCO JACK
BEFORE SERVICING THIS PANEL.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC3 USA-40133-SP-T
RINGER EQUIVALENCE: 1.0B
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
1
2
3
4
Refer to UVS Installation and Setup Guide K4214 for complete information
GRAY
BROWN
UVCM_UVST-SOC-V1
INCOMING
TELCO
LINES
ALTERNATE
+12 VDC IN FOR
PLUG-IN WALL PACK
(SEE NOTE 2)
Figure 3-28: UVS Connections to the Control Panel
Connecting the Transformer
This product uses the 1361 transformer (1361CN in
Canada). If you are using X-10 devices, the 1361X10
transformer interface must be used instead of the
regular 1361 transformer. The 1361X10 supplies the
control panel with AC, and also sends control pulses
through the premises electrical system to control the X-
10 devices.
U
L
Use 1361CN Transformer in Canadian
installations.