Honeywell 3.5 Home Security System User Manual


 
VISTA-40 Installation and Setup Guide
4-4
Zone Number Designations
The VISTA-40 supports up to 64 zones of hardwire,
polling loop and/or wireless protection, distributed
among up to 2 partitions. The following table lists the
zone numbers and the types of sensors that can be used
with each, and some alternate functions of the zones.
Zone Function
1 2-wire Smoke Detectors (if used)
5 Audio Alarm Verification (if used)
7 Keyswitch (if used)
8 Latching-Type Glassbreak Detectors (if used)
1-9 Traditional Hardwired Zones
1-64 5800 Series Wireless Devices
10-64 Polling Loop Devices
95
+ 1 Panic
96 # + 3 Panic
99
+ # Panic
Zone Defaults
Zone # Zone Type Zone # Zone Type
01 09 70 00
02 03 87 00
03 03 88 00
04 03 90 00
05 03 91 00
06 03 92* N/A
07 03 95 00
08 03 96 00
09 03 97 05
1064 00 99 06
NOTES: * Zone 92 is the Duress zone. Programming of the
zone response type is not applicable. This zone requires only
the report code programming.
Zone Index
The zones are designated as follows:
ZONE #
RANGE
ZONE
FUNCTION
ACTUAL ZONE
01 64 Protection
zones
As indicated
70, 88, 89,
90, 91, &
97
System
Supervisory
Zones
70: Bell Supervision
88: 2
nd
Wireless Receiver
not receiving signals
89: 2
nd
Wireless Receiver
not talking to control
90: 1
st
Wireless Receiver
not receiving signals
91: 1
st
Wireless Receiver
not talking to control
97: Polling Loop (short
circuit)
92, 95, 96,
& 99
Duress and
Keypad Panics
92: Duress
95: 1 + panic (A key)
96: 3 + # panic (C key)
99: + # panic (B key)
Supervisory zones should be given a response type of 05
(Trouble by Day, Alarm by Night).
Communication Defaults
*45 PRIMARY FORMAT [1] ADEMCO Contact ID
*46 LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed
*47 SECONDARY FORMAT [1] ADEMCO Contact ID
*48 LOW SPEED FORMAT (Sec.) [0] ADEMCO Low Speed
*49 CHECKSUM VERIFICATION [0] [0]
No checksum Primary Secondary
*50 SESCOA/RADIONICS SEL. [0] Radionics
*51 DUAL REPORTING [0]
no
*52 STANDARD/EXPANDED REPORT FOR PRIMARY
[0] [0] [0] [0] [0] [0] standard
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
*53 STANDARD/EXPANDED REPORT FOR SECONDARY
[0] [0] [0] [0] [0] [0] standard
Alarm Rstr Bypass Trbl Opn/Cls Low Bat