Honeywell 3.5 Home Security System User Manual


 
Section 3 - Installing the Control
3-21
To install the VIP module, perform the following steps:
Step Action
1 Mount the module in the control cabinet if
space is available or, if this is not possible, on
the side of the cabinet or adjacent to it.
If you mount the VIP Module inside the
control cabinet, attach it to the cabinets
interior surface with 2-faced adhesive tape.
You may leave the modules cover off if it is
mounted within the cabinet.
If you mount the module outside the
cabinet, use the screw holes at the rear to
mount horizontally or vertically (2-faced
adhesive tape may be used, if preferred).
2 Affix the 4285/4286 connections label
(supplied separately) to the inside of the VIP
Modules cover, if the cover is used.
Otherwise, affix the label to the inside of the
control cabinet’s door.
3 Make 12V (+) and () and data-in and data-
out connections from the VIP Module to the
control, using the connector cable supplied
with the VIP Module. These are the same
connections as for remote keypads.
Step Action
Connect the module to the phone line as
shown below. See Figure 3-27.
4285/4286 Terminal Connects to direct
connect cord:
1. Phone In (Tip) green wire
2. Phone In (Ring) red wire
3. Phone Out (Tip) brown wire
4. Phone Out (Ring) gray wire
5. No Connection
6. Audio Out 1 Speaker
7. Audio Out 1 Speaker
Supported by the 4286 only
4
Use an RJ31X Jack with the phone cable
supplied with the control to make connections
to the VIP module. Make connections exactly
as shown in Figure 3-27. This is essential,
even if the system is not connected to a
central station. The 4285/4286 will not
function if this is not done.
If touch-tones are not present following phone
access to the security system via an on-
premises phone, try reversing the pair of
wires connected to terminals 3 and 4 on the
4285/4286.
If the phone plug is disconnected from the
control, the premises phones will not operate.
YELLOW
NO CONNECTION
RED
BLACK
GREEN
TO CONTROL PANEL
KEYPAD CONNECTIONS
KEYED
HEADER
123456 7
NO
CONNECTION
4286 VIP MODULE
ANSWERING
MACHINE
PREMISES
ANSWERING
MACHINE AND
PHONES
TIP
RING
RJ31X
JACK
TIP
RING
INCOMING TELCO LINE
CALLER ID
UNIT
IMPORTANT NOTE FOR EXISTING INSTALLATIONS:
EXISTING WIRES CONNECTED TO THE HANDSET
TERMINALS ON CONTROL MUST BE MOVED FROM
THERE TO TERMINALS 3 AND 4 ON THE 4286.
U.S.PATENT No. 4791658
THIS DEVICE COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No. AC3USA-74659-KX-N
RINGER EQUIVALENCE: 1.0B
FOR COMPLETE INFORMATION, SEE INSTALLATION
INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP
MODULE
GREY
BROWN
GREEN
RED
EARTH
GROUND
TIP RING TIP RING
4500
THERMOSTAT
GREEN
YELLOW
HANDSETINCOMING
TELCO LINE
NOTE:
4286 DEVICE
ADDRESS IS
FACTORY SET
TO 4
SEE SPEAKER NOTE
SPEAKER NOTE: IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY.
IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS
AND CONNECT IN SERIES.
SPEAKER
VOLUME
CONTROL
4286_wiring-002-V1
Figure 3-27: VIP Module Connections