VISTA-40 Installation and Setup Guide
5-6
FIELD
TITLE and DATA ENTRIES EXPLANATION
*52
Standard/Expanded Reporting
Primary
0 = disable
1 = enable
This field has six entries as follows: Alarm, Restore, Bypass, Trouble,
Open/Close, Low Battery. If enabled, expanded reports are sent to the
primary phone number if low speed format is selected in field *45.
NOTE: Expanded overrides 4+2 format.
*53
Standard/Expanded Reporting
Secondary
0 = disable
1 = enable
This field has six entries as follows: Alarm, Restore, Bypass, Trouble,
Open/Close, Low Battery. If enabled, expanded reports are sent to the
secondary phone number if low speed format is selected in field *47.
NOTE: Expanded overrides 4+2 format.
*54
Alarm Code for Zones 01–08
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*55
ID Digit for Zones 01–08
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*56
Alarm Code for Zones 09–16
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*57
ID Digit for Zones 09–16
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*58
Supervisory and Restore Codes
for Zones 01–16
Enter 00-15.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
NOTE: Each report code is the same for zones 01-16. When using 4+2
format, the system uses the ID digit of the zone (fields *55 and *57).
*59
Alarm Code for Zones 17–24
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*60
ID Digit for Zones 17–24
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*61
Alarm Code for Zones 25–32
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*62
ID Digit for Zones 25–32
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*63
Supervisory and Restore Codes
for Zones 17–32
Enter 00-15.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
NOTE: Each report code is the same for zones 17-32. When using 4+2
format, the system uses the ID digit of the zone (fields *60 and *62).
*64
Alarm Code for Zones 33–40
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*65
ID Digit for Zones 33–40
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*66
Alarm Code for Zones 41–48
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
*67
ID Digit for Zones 41–48
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.