Honeywell 3.5 Home Security System User Manual


 
VISTA-40 Installation and Setup Guide
5-8
FIELD
TITLE and DATA ENTRIES EXPLANATION
*82
Non-Alarm Report Codes
(Second Digit
Enter 00-15.
This field has ten two-digit entries as follows: Close, Open, Low Battery,
Low Battery Restore, AC Loss, AC Restore, Test, Power-up, Cancel, and
Program Tamper. Enter the report code 01-15 for each type of report.
Enter 00 for no report.
*83
First Test Report Time
Enter 00-07 the for day (01 = Monday)
Enter 00-23 for the hour
Enter 00-59 for the minutes
Enter the day and time that the first Test report shall be transmitted.
Enter 00 in all locations if the Test report is to be sent immediately upon
exiting. Enter 00 in the day location if the report is to be sent at the next
occurrence of the time that is set.
*84
Swinger Suppression (partition-
specific)
Enter 01-15.
Enter 00 for unlimited reports
This option limits the number of messages (alarms or troubles) sent for a
specific zone in an armed period.
Must be 00 for UL installations.
*85
Enable Dialer Reports for Panics
& Duress (partition-specific)
0 = disable
1 = enable
This field has four entries as follows: Zone 95, 96, 99, and Duress. Enable
for each partition that the panics and duress reporting is desired.
NOTE: Non-zero report code must be assigned to zone 92 to enable
Duress reporting.
Entering 1 allows a single 4208 to be set to zone numbers 10-17, but
precludes the use of any other polling loop devices.
Entering 0 allows all other configurations, such as no 4208, more than
one 4208, or other polling loop expansion present.
4208 Zone #s available when: When *86 = 1 4208 DIP switches must be set to:
*86 = 1 *86 = 0
With word OFF With word ON
10-17 10-16
sw 2 = ON sw 2 = OFF
17-24
sw 3 = ON sw 3 = OFF
25-32
sw 4 = ON sw 4 = OFF
33-40
sw 5 = OFF sw 5 = ON
41-48
49-56
Precludes use
of any other
polling loop
expansion
57-64
*86
4208 Module Zone Assignment
0 = other configurations
1 = 10-17 only
*87
Entry Warning (partition-specific)
0 = 3 short beeps
1 = slow continuous beeps
Select the type of warning for the entry delay period.
*88
Burglary Alarm Communicator
Delay (partition-specific)
0 = no delay
1 = 16-second delay
Select the delay, if any, for burglary alarm communications.
Must be 0 for UL installations.
*89
Restore Report Timing
0 = instant
1 = after bell timeout
2 = when system is disarmed
Select the time when restore reports are sent after an alarm.
Must be 2 for UL installations.
*90
Secondary Subscriber Account
Number (partition-specific)
Enter 00-09; B-F (11-15)
Enter a 3- or 4-digit (depending on report format) secondary subscriber
account number. Each number requires a 2-digit entry so as to allow
entry of hexadecimal digits (B-F). If a 3-digit account number is to be
used, enter data only in the first 3 locations, and enter * in the fourth
location.
NOTE: This field must be programmed if a secondary phone number is
used (field *34). This account number can be the same as the primary
account number.