79
-
2) Single-phase 200V input series
Item Specifications
Drive HP 1/8 1/4 1/2 1 2 3
Nominal applied motor
*1 (HP)
1/8 1/4 1/2 1 2 3
Rated output
capacity *2 (kVA)
0.28 0.56 1.0 1.6 2.8 4.0
Voltage(V) 3-phase, 200V/50Hz, 200, 220, 230V/60Hz (Proportional to input voltage)
Rated current (A) 0.7 1.4 2.5 4.0 7.0 10.0
Overload capacity 150% of rated current for 1 min.
Output ratings
Rated frequency (Hz) 50, 60Hz
Phases, Voltage, Fre-
quency
Single-phase 200 to 240V 50/60Hz
Voltage/frequency
variations
Voltage: +10% to 10%, Frequency: +5% to 5%
Capability for voltage
dip *3
When the input voltage drops 165V or more, the drive can be operated continuously.
When the input voltage drops below 165V from rated voltage, the drive can be operated
for 15ms.
1.2 2.0 3.5 6.5 11.8 17.7
Rated input current *6
(with DCR)
(without DCR)
2.3 3.9 6.4 11.4 19.8 28.5
Input power supply
Required power sup-
ply capacity *4 (kVA)
0.3 0.4 0.7 1.3 2.4 3.6
Braking torque
*5 (%)
150 100 50 30
Braking
DC injection
braking
Starting frequency: 3Hz(fixed), Braking current (0 to 100%),
Braking current ( 0 to 30%)
Protective structure
(IEC60529)
Closed type IP20
Cooling method Self-cooling Fan cooling
Weight (Lb) 1.3 1.3 1.5 2.0 3.5 4.9
Notes:
*1 A 4-pole standard motor is assumed as a nominal applied motor.
*2 Drive output capacity (kVA) at 230V.
*3 When a momentary power failure occurs, while rated voltage is applied 85% of load of nominal motor is
given.
*4 When an optional power-factor correcting DC reactor is used.
*5 Average braking torque where an unloaded motor decelerates and stops from 60Hz
operation. (Varies according to the motor efficiency)
*6 The specification is calculated on assumption that the drive is connected to a 500 kVA -equivalent power
transformer.
*7 The inter-phase imbalance ratio (%) = ((Max. voltage) - (Min. voltage)) / (Average voltage among three
phases) x 67