Change during operation: N = impossible, Y* = possible (enabled by using ),
Y
= possible (enabled by using
)
-
41
-
FUNC
DATA
Maximum output frequency
This function sets the maximum output frequency.
5 0
to The maximum output frequency can be set with a resolution of 1 Hz in a range between 50
and 120 Hz.
1 2 0
!
CAUTION
High-speed operation can be set by the drive easily. Carefully check the limit of the motor and machine
before changing the setting,
otherwise injuries could occur.
F03
f Maximum output frequency
V
Maximum voltage
Factory
setting
Change during
operation
60Hz
N