GE AF-300 Sewing Machine User Manual


 
Change during operation: N = impossible, Y* = possible (enabled by using ),
Y
= possible (enabled by using
)
-
49
-
FUNC
DATA
Starting frequency
Stop frequency
These functions set a starting or stop frequency in a range
from 1 to 6Hz in 1Hz step.
1
1Hz
to
6 6Hz
Data cannot be
changed.
Motor sound
(carrier freq.)
This function changes the motor tone quality by changing the carrier frequency.
0
to Choose among 16 types according to the usage conditions.
1 5
Data code 0 : 0.75kHz (Low carrier)
1 : 1kHz
2 : 2kHz
15 : 10kHz (High carrier, low noise)
Note: When the drive is operating at 9kHz or higher carrier frequency, the carrier
frequency for may be reduced to 8kHz automatically to protect the drive.
Starting frequency stop frequency
Starting
frequency setting
Stop
frequency setting
t Output frequency in forward/
reverse operation
0.2Hz
Stop frequency setting
Starting frequency setting
Starting frequency setting
Stop frequency setting
FWD
REV
Starting frequency < stop frequency
Stop
frequency setting
Starting
frequency setting
t
If the set frequency is lower than the stop fre
quency,
the drive output is 0Hz.
F26
F24
Factory
setting
Change during
operation
0.0
-
F23
F25
Factory
setting
Change during
Operation
1Hz
N
F23
F25
1Hz
N
Factory
setting
Change during
operation
2kHz
Y