GE AF-300 Sewing Machine User Manual


 
Change during operation: N = impossible, Y* = possible (enabled by using ),
Y
= possible (enabled by using
)
-
47
-
FUNC
DATA
Gain
(for frequency setting signal)
This function outputs the frequency obtained by multiplying the reference frequency by a ratio.
This function selects an analog input signal level with a value from
1
to
4
that is set by function
F 0 1
.
0
The maximum frequency is output at +10Vdc (20mA dc).
1
The maximum frequency is output at +5Vdc (12mAdc).
When this function is used with function
F 1 8
(bias frequency ), the gain set with this function is
valid and the gained frequency is biased.
Bias frequency
This function outputs a frequency biased for the analog frequency setting.
-1 2 0
to
1 2 0
Factory
setting
Change during
operation
0
N
-120 to 120Hz can be set with a resolution of 1Hz.
Factory
setting
Change during
operation
0
Y
0%
Bias (negative)
0
4
+10Vdc
20mAdc
100%
Frequency set-
ting
Bias (positive)
F17
100%
Frequency
setting
+10Vdc +5 0
20mAdc 12 4
1
0
F18