First Alert FA134OC-UL Home Security System User Manual


 
FIRE ALARM SYSTEM (IF INSTALLED)
-
m
I
General Your fire alarm system (if installed) is on 24 hours a day, providing continuous
protection. In the event of an emergency, the installed smoke and heat detectors will
automatically send signals to your Control/Communicator, triggering a loud, interrupted
sound from the Keypad. An interrupted sound will also be produced by optional exterior
sounders. A FIRE message will appear at your Keypad and remain on until you silence
the alarm.
In Case Of Fire 1.
Alarm
2.
3.
4.
Silencing A Fire 1.
Alam
2.
3.
4.
Should you become aware of a fire emergency before your detectors sense the
problem, go to your nearest Keypad and manually initiate an alarm by pressing the
panic key pair assigned as FIRE emergency (if programmed by the installer) and
hold down for at least 2 seconds.
Evacuate all occupants from the premises.
If flames and/or smoke are present, leave the premises and notify your local Fire
Department immediately.
If no flames or smoke are apparent, investigate the cause of the alarm. The zone
descriptor of the zone(s) in an alarm condition will appear at the Keypad.
Silence the alarm by entering your code and pressing the OFF key. To clear the
display, enter your code and press the OFF key again.
If the Keypad does not indicate a READY condition after the second OFF sequence,
press the READY key to display the zone(s) that are faulted. Be sure to check
that smoke detectors are not responding to smoke or heat producing objects in their
vicinity. Should this be the case, eliminate the source of heat or smoke.
If this does not remedy the problem, there may still be smoke in the detector. Clear it
by fanning the detector for about 30 seconds.
When the problem has been corrected, clear the display by entering your code and
pressing the OFF key.