TABLE 2 — PHYSICAL DATA 48HE (cont)
BASE UNIT 48HE HD/E/F003 HE/F/H/K/M/N004 HD/E/F/G/H/K/L/M/N005 HD/E/F/G/H/K/L/M/N006
FURNACE SECTION
Rollout Switch CutoutTemp (F)†
195 195 195 195
Burner Orifice Diameter (in. ...drill size)**
Natural Gas — Std* HJE .113...33 HJD .113...33 HJD .113...33
HEE .089...43 HJF .113...33 HJE .113...33 HJE .113...33
HJF .129...30 HJF .129...30
HJH .113...33 HJG .113...33 HJG .113...33
HJK.113...33 HJH .113...33 HJH .113...33
HJK .129...30 HJK .129...30
HEM .0 8 9 ...4 3
HJM .102...38 HJL .102...38 HJL .102...38
HJN.102...38 HJM .102...38 HJM .102...38
HJN .116...32 HJN.116...32
LiquidPropane — Alt†† HEE .073...49 HJE .089...43 HJD .089...43 HJD .089...43
HJF .089...43 HJE .089...43 HJE .089...43
HJF .104...37 HJF .104...37
HJH .089...43 HJG .089...43 HJG .089...43
HJK.089...43 HJH .089...43 HJH .089...43
HJK .102...37 HJK .104...37
Thermostat Heat Anticipator Setting (amps)
208/230/460/575 v
First Stage
.14 .14 .14 .14
Second Stage
.14 .14 .14 .14
GasInput (Btuh)
First Stage/Second Stage
HEE 50,000/--- HEE||
50,000/ 72,000
HED|| 50,000/ 72,000 HED|| 50,000/ 72,000
HEF||
82,000/115,000
HEE|| 82,000/115,000 HEE|| 82,000/115,000
HEF|| 120,000/150,000 HEF|| 120,000/150,000
HEH*** —/ 72,000 HEG*** —/ 72,000 HEG*** —/ 72,000
HJK***—/115,000 HEH*** —/115,000 HEH*** —/115,000
HEK*** —/150,000 HEK*** —/150,000
HEM††† —/ 60,000 HEL††† —/ 60,000 HEL††† —/ 60,000
HEN††† —/ 90,000 HEM††† —/ 90,000 HEM†††—/ 90,000
HEN††† —/120,000 HEN††† —/120,000
Efficiency (Steady State) (%) HEE 81 HEE 82.8 HED 82.8 HED 82.8
HEF 80 HEE 81 HEE 81
HEF 80.4 HEF 80.4
HEH 82 HEG 82 HEG 82
HEK 80 HEH 81 HEH 81
HEK 80 HEK80
HEM 80.2 HEL 80.2 HEL 80.2
HEM 81
HEN81 HEM 81 HEM 81
HEN 80.7 HEN80.7
TemperatureRiseRange HEE 25-55 HED 25-25 HED 25-55
HEE 25-65
HEF 55-85 HEE 35-65 HEE 35-65
HEF 50-80 HEF 50-80
HEH 25-55 HEG 25-55 HEG 25-55
HEK 55-85 HEH 35-65 HEH 35-65
HEK 50-80 HEK 50-80
HEM 20-50 HEL 20-50 HEL 20-50
HEN30-60 HEM 30-60 HEM 30-60
HEN40-70 HEN 40-70
Manifold Pressure (in. wg)
Natural Gas — S td
3.5 3.5 3.5 3.5
LiquidPropane — Alt††
3.5 3.5 3.5 3.5
Maximum Static Pressure (in. wg)
1.0 1.0 1.0 1.0
Field Gas Connection Size (in.)
1
/
2
1
/
2
1
/
2
1
/
2
HIGH-PRESSURE SWITCH (psig)
Standard Compressor Internal Relief
450 50
Cutout
428
Reset (Auto.)
320
LOSS-OF-CHARGE SWITCH (LiquidL Ine) (psig)
Cutout
7 3
Reset (Auto.)
22 5
FREEZE PROTECTION THERMOSTAT
Opens (F)
30 5
Closes (F)
45 5
OUTDOOR-AIR INLET SCREENS
Cleanable. Screen quantity and s ize varies with option selected.
RETURN-AIR FILTERS
Throwaway
Quantity...Size (in.)
2...16 x 25 x 2
LEGEND
Bhp — Brake Horsepower
*Stainlesssteel models usesameorificesasequivalent standard unit.
†Indicatesautomaticreset.
**72,000 Btuh heat input units have 2 burners. 90,000 and 120,000 Btuh heat
input units have 3 burners. 115,000 Btuh heat input units and 150,000 Btuh Heat
input units have 3burners.
††AnLPkitisavailableasanaccessory. AnLPconversionkitshouldnotbeusedona
low NOx unit because then it can no longer be classified as a Low NOx unit. The
LowNOx requirement only applies to natural gas units.
Three-phasestandard modelshave heatinginputs as shown. Single-phasestandard
models have one-stage heating withheatinginput valuesas showninheatincapac-
itytables.
***Theseunitsdo NOT meettheCalifornia lowNOxrequirements.
†††California SCAQMD compliant low NO
x
modelshave combustion products that are
controlledto 40nanogramsperjouleor less.
48HE,HJ