Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 1.0 Introduction EN | 9
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
1.2 Quick Start
The following steps allow you to use the ICP-CC488
Control Panel with factory default values. The default
values allow the control panel to communicate in the
Contact ID format. If you are not familiar with
programming the control panels, read the
information in Section 7.0 Programming before starting
the installation.
After all wiring is complete, connect the AC plug
pack to the control panel.
Both the MAINS and AWAY indicators are lit.
The MAINS indicator lights to indicate the AC
MAINS supply is connected.
The AWAY indicator lights to signify the system
is armed in AWAY Mode.
If any 24-Hour zones are unsealed when you
power up the system, the Siren, Strobe, and Bell
Outputs are activated into alarm and the
corresponding zone indicator flashes.
Enter the default Master Code (2580) and press
[AWAY] to disarm the system and to reset any
alarm that occurred when you powered up the
system.
The AWAY indicator is extinguished to signify
that the system is disarmed.
If any zone indicator is flashing, an alarm
occurred in that zone.
If a zone indicator is lit constantly, the zone is
unsealed.
Connect the backup battery.
Enter the default Installer Code (1234) and press
[AWAY].
Two beeps sound and the STAY and AWAY
indicators flash simultaneously to indicate that
you entered Installer’s Programming Mode.
When entering Installer’s Programming Mode,
you are automatically positioned at Location 000,
the first digit of the Primary Telephone Number
for Receiver 1.
Enter the Primary Telephone Number, the
Secondary Telephone Number, and the
Subscriber ID Number for Receiver 1.
Refer to Sections 11.1, 11.2, and 11.5 for more
information about programming these numbers.
When programming the telephone numbers for
Receiver 1 and Receiver 2, you must program a
0 as a 10. Programming a 0 in the telephone
number indicates the end of the dialing
sequence. Unless otherwise stated, program a 0
as a 0 in all locations other than the telephone
numbers for Receiver 1 and Receiver 2, and the
Call Back Telephone Number.
If required, set the Test Report time.
Program any other required changes. Otherwise,
factory default settings are used. Refer to Section
15.28 Test Reporting Time for more information.
Enter command [9 6 0] and press [AWAY] to exit
from Installer’s Programming Mode.
Two beeps sound and the STAY and AWAY
indicators are extinguished. The system is
returned to the disarmed state and is ready for
use. Refer to Section 7.4 Installer’s Programming
Commands for more information.
Use the Master Code to set the date and time.
Refer to Section 1.2.1 Set the Date and Time for
more information.
1.2.1 Set the Date and Time
1. Enter your Master Code and press [6][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the day, month, year, hour, and minute in
DD, MM, YY, HH, MM format (where DD is
the day of the month, MM is the month of the
year, YY is the year, HH is the hour of the day,
and MM minute of the day) and press [AWAY].
Use 24:00 hour format when programming the
hour of the day.
Two beeps sound and the STAY and AWAY
indicators are extinguished. If a long beep
sounds, there was an error when you entered the
date and time.
Example
To set the date and time for the 1st January 2004 at
10:30 PM, enter:
[2 5 8 0
6][AWAY][0
1 0 1 0
4 2
2
3
0][AWAY]
1.2.2 ICP-CC488 Zone Defaults
The default zone settings for the control panel are
listed in Table 1
on page 9. You can program Zones 1
to 8 to any of the zone types. Refer to Table 2 on
page 10 for the zone types you can select.
Table 1: Zone Defaults for the ICP-CC488
Zone Zone Type Zone Zone Type
1 Delay-1 5 Instant
2 Handover 6 Instant
3 Handover 7 Instant
4 Handover 8 24-Hour Tamper