Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 10.0 Dialer Reporting Formats EN | 45
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Table 42: 4 + 2 Transmission Code
Descriptions
Code Description
SSSS Subscriber ID Number
A Alarm
C
H
Channel Number
1
0 Zero
T Trouble
B Bypass
E AC Fail Code 1
st
digit
AC AC Fail Code 2
nd
digit
L Low Battery Code 1
st
digit
L
B
Low Battery Code 2
nd
digit
O Open
C Close
U User Number
R Alarm Restore Code
TR Trouble Restore Code
B
R
Bypass Restore Code
E
R
AC Fail Restore Code 1
st
digit
AC
R
AC Fail Restore Code 2
nd
digit
L
R
Low Battery Restore Code 1
st
digit
L
BR
Low Battery Restore Code 2
nd
digit
D Duress Code 1
st
digit
D
0
Duress Code 2
nd
digit
P Panic Code 1
st
digit
P
CH
Panic Code 2
nd
digit
T
E
Test Code
1
0=Zone 16, 1=Zones 1 through 15. Some receivers
might need to have parameters set to 0 for Zone 16
10.1.5 Basic Pager Reporting Format
Although Basic Pager Format requires some
interpretation of the numbers that appear on the
display, it is possible to differentiate among 1000
different control panels if a number of control panels
report to the one pager.
To set up Receiver 1 for basic pager reporting:
1. Program the Basic Pager’s access telephone
number in Locations 000 to 015 (refer to Section
11.1 Primary Telephone Number for Receiver 1 and
Receiver 2 on page 49).
2. Program the Subscriber ID Number in Locations
034 to 039 (refer to Section 11.5 Subscriber ID
Number for Receiver 1 and Receiver 2 on page 50).
3. Select the Pager Handshake option (5) in
Location 032 (refer to Section 11.3 Handshake Tone
for Receiver 1 and Receiver 2 on page 49).
4. Program the Basic Pager Format option (5) in
Location 033 (refer to Section 11.4 Transmission
Format for Receiver 1 and Receiver 2 on page 50).
To set up Receiver 2 for basic pager reporting:
1. Program the Basic Pager’s access telephone
number in Locations 040 to 055 (refer to Section
11.1 Primary Telephone Number for Receiver 1 and
Receiver 2 on page 49).
2. Program the Subscriber ID Number in Locations
074 to 079 (refer to Section 11.5 Subscriber ID
Number for Receiver 1 and Receiver 2 on page 50).
3. Select the Pager Handshake option (5) in
Location 072 (refer to Section 11.3 Handshake Tone
for Receiver 1 and Receiver 2 on page 49).
4. Program the Basic Pager Format option (5) in
Location 073 (refer to Section 11.4 Transmission
Format for Receiver 1 and Receiver 2 on page 50).
The example in Figure 9 on page 47 shows:
A transmission from Subscriber ID
Number 5678
Zone 2 is in alarm
Zone 3 is manually isolated
The system is armed
The Panic Zone is normal
The AC is connected
There is no fault condition.