Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 13.0 Access Codes EN | 55
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Location
185 to 264
Location Default
User Code 1 185 2
186 5
187 8
188 0
Priority Level 189 10
User Code 2 190 to 193 15
Priority Level 194 2
User Code 3 195 to 198 15
Priority Level 199 2
User Code 4 200 to 203 15
Priority Level 204 2
User Code 5 205 to 208 15
Priority Level 209 2
User Code6 210 to 213 15
Priority Level 214 2
User Code 7 215 to 218 15
Priority Level 219 2
User Code 8 220 0
221 to 223 15
Priority Level 224 3
User Code 9 225 to 228 15
Priority Level 229 2
User Code 10 230 to 233 15
Priority Level 234 2
User Code 11 235 to 238 15
Priority Level 239 2
User Code 12 240 to 243 15
Priority Level 244 2
User Code 13 245 to 248 15
Priority Level 249 2
User Code 14 250 to 253 15
Priority Level 254 2
User Code 15 255 to 258 15
Priority Level 259 2
User Code 16 260 to 263 15
Priority Level 264 2
13.3 User Code Priority
The installer can assign one of ten different priority
levels to a User Code. Each priority level allows or
restricts a user from performing specific functions.
Table 47: Priority Levels
Priority
Level
Description
0 Arm/disarm
1 Arm only
2 Arm/disarm and Open/Close Reports
3 Arm only and Close Report
4 Arm/disarm and code to isolate
6
Arm/disarm, code to isolate, and Open/Close
Reports
8 Arm/disarm and Master Code functions
10
Arm/disarm, Master Code functions, and
Open/Close Reports
12
Arm/disarm, Master Code functions, and code
to isolate
14
Arm/disarm, Master Code functions, code to
isolate, and Open/Close Reports
Arm/Disarm
The user can arm and disarm the system. A Closing
Report is sent only after a previous code with the
ability to send an Opening Report disarms the
system.
Arm Only
The user can arm the system but cannot disarm the
system. A Closing Report is sent only after a previous
code with the ability to send an Opening Report
disarms the system.
Open/Close Reports
Open and Close Reports are sent to the monitoring
station when the user disarms and arms the system,
but only if Open/Close Reports is enabled in
Locations 401 and 402 (refer to Section 15.13
Open/Close Reports on page 67).
Code To Isolate
If one or more User Codes include this option, the
method of standard isolating is disabled and only a
User Code with this option in its priority level can
isolate zones before arming the system using the
Code to Isolate method. Refer to Section 3.11 Isolating
Zones on page 17 for more information.
When priority level 4, 6, 12, or 14 is
assigned to any User Codes, the
Standard Isolating method no longer
operates. Only User Codes with a priority
level of 4, 6, 12, or 14 can isolate zones
using the Code to Isolate method.