Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 25.0 Programming Sheets EN | 101
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Disconnect this equipment immediately if it
becomes physically damaged and arrange for its
disposal or repair.
The transmit level from this device is set at a
fixed level, so there may be circumstances where
the performance is less than optimal. Before
reporting such occurrences as faults, please check
the line with a standard telepermitted telephone
and do not report a fault if the telephone
performance is satisfactory.
This device is equipped with pulse dialing while
the Telecom standard is DTMF tone dialing.
There is no guarantee that Telecom lines will
always continue to support pulse dialing.
Use of dialing, when this equipment is connected
to the same line as other equipment, may give
rise to bell tinkle or noise and may also cause a
false answer condition. If problems such as this
occur, the user should not contact the Telecom
Faults Service.
This equipment is set up to carry out test calls at
pre-determined times. These test calls interrupt
other calls that might be set up on the line at the
same time. Discuss the timing set for these test
calls with the installer.
The timing set for test calls from this equipment
may be subject to drift. If this proves to be
inconvenient and your calls are interrupted,
discuss the problem of timing with the
equipment installer. Do not report the matter as
a fault to Telecom Faults Service.
This equipment shall not be set up to make
automatic calls to the Telecom 111 Emergency
Service.
This equipment should not be used under any
circumstances that may constitute a nuisance to
other Telecom customers.
In the event of any problem with this device,
disconnect the system battery, AC MAINS
supply, and the telephone line. The user must
arrange with the supplier of the device for the
necessary repairs.
If the matter is reported to Telecom as a wiring
fault and the fault is proven to be due to this
product, a call-out charge will be incurred.
24.5 A-Tick
The ICP-CC488 Control Panel is designed to comply
with A-Tick.
25.0 Programming Sheets
25.1 ICP-CC488 Programming Sheets
Primary Telephone Number for Receiver 1
Location
000 to 015 Refer to page 49
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Secondary Telephone Number for Receiver 1
Location
016 to 031 Refer to page 49
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Handshake Tone for Receiver 1
Location
032 Refer to page 49
1 HI-LO handshake (contact ID)
2 1400 Hz (Ademco TX @ 1900 Hz)
3 2300 Hz (Low Speed Sescoa)
4 No handshake
5 Pager
Transmission Format for Receiver 1
Location
033 Refer to page 50
1 Contact ID
2 4 + 2 express
3 FSK 300 baud
4 Domestic
5 Basic pager
6 Reserved
7 Reserved
8 Reserved
The Basic Pager option supports only
eight zones due to protocol limitations. If
you use more than eight zones, this option
is not recommended.
If you use the Zone 16, the 4 + 2 Express
and FSK 300 Baud formats are not
recommended because Zone 16 will be
assigned as "0" and some receivers will
not support this zone.
Subscriber ID Number For Receiver 1
Location
034 to 039 Refer to page 50
Default
0 0 0 0 0 0
Primary Telephone Number for Receiver 2
Location
040 to 055 Refer to page 49
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Secondary Telephone Number for Receiver 2
Location
056 to 071 Refer to page 49
Default
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Handshake Tone for Receiver 2
Location
072 Refer to page 49
1 HI-LO handshake (contact ID)
2 1400 Hz (Ademco TX @ 1900 Hz)
3 2300 Hz (low speed Sescoa)
4 No handshake
5 Pager