ICP-CC488 | Installation Guide | 19.0 Partitioning EN | 86
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
19.4.1 Zone Allocations for Areas 1 and 2
Location
502 to 517
Location Default
Zone 1 LED – Area 1 Codepad 502 0
Zone 2 LED – Area 1 Codepad 503 0
Zone 3 LED – Area 1 Codepad 504 0
Zone 4 LED – Area 1 Codepad 505 0
Zone 5 LED – Area 1 Codepad 506 0
Zone 6 LED – Area 1 Codepad 507 0
Zone 7 LED – Area 1 Codepad 508 0
Zone 8 LED – Area 1 Codepad 509 0
Zone 1 LED – Area 2 Codepad 510 0
Zone 2 LED – Area 2 Codepad 511 0
Zone 3 LED – Area 2 Codepad 512 0
Zone 4 LED – Area 2 Codepad 513 0
Zone 5 LED – Area 2 Codepad 514 0
Zone 6 LED – Area 2 Codepad 515 0
Zone 7 LED – Area 2 Codepad 516 0
Zone 8 LED – Area 2 Codepad 517 0
0
1
Not mapped for this LED
A zone is mapped to this LED
You can enable or disable the zone allocations for
Area 1 and Area 2. For example, if the location 507
is set to “0”, the zone LED of Area 1 is not mapped.
Detailed Example
In the following example, Zones 1, 2, 3, and 4 are
allocated to Area 1 to appear as zones 1, 2, 3 and 4.
Zones 1, 5, 6, 7, 8 are allocated to Area 2 to appear
as zones 1, 5, 6, 7, and 8. Programming the same
zone into more than one area specifies that zone as a
common zone.
Figure 18: Area 1 Codepad Display
Area 1 Zone Allocations
Locations 502 to 509: 1 2 3 4 0 0 0 0
Figure 19: Area 2 Codepad Display
Area 2 Zone Allocations
Locations 510 to 517: 1 0 0 0 5 6 7 8
19.5 User Code Allocations
Location
534 to 549
Location Default
User Code 1 534 0
User Code 2 535 0
User Code 3 536 0
User Code 4 537 0
User Code 5 538 0
User Code 6 539 0
User Code 7 540 0
User Code 8 541 0
User Code 9 542 0
User Code 10 543 0
User Code 11 544 0
User Code 12 545 0
User Code 13 546 0
User Code 14 547 0
User Code 15 548 0
User Code 16 549 0
Locations 534 to 549 are used to assign each User
Code to one or two area areas of a partitioned ICP-
CC488 Control Panel. Enter a value from 0 to 3 into
each of these locations to assign the User Code
holder to the areas it must operate (refer to Table 61).
You can allocate multiple User Codes to the same
area.
Table 61: User Code Allocations
Option Description
0 Not allocated to an area
1 Allocated to Area 1
2 Allocated to Area 2
3 Allocated to Area 1 and Area 2
19.6 Setting Up and Programming
Codepads for Partitioning
Only the CP5 Area Addressable (CP500A) and CP5
Master Partitioned (CP500P) codepads can be used
with a partitioned ICP-CC488 Control Panel.