Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 15.0 System Reporting Information EN | 68
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Restore Reports are not sent for this
event.
If Codepad Panic Reports are not
required, program Locations 405 and 406
as 0.
15.17 Codepad Fire Report
Location
407 to 408
Location Default
Tens digit 407 7
Units digit 408 14
A Fire Alarm Report (Contact ID Event Code 110) is
sent to the base station receiver when a user presses
[4] and [6] at the same time. A Fire Alarm is audible,
but you can program the alarm as silent by selecting
Option 2 in Location 493 (refer to Section 18.2 System
Options 2 on page 81). A distinct fire sound is emitted
through the horn speaker to indicate this type of
alarm. The fire sound is different than the burglary
sound.
Restore Reports are not sent for this
event.
If Codepad Fire Reports are not required,
program Locations 407 and 408 as 0.
15.18 Codepad Medical Report
Location
409 to 410
Location Default
Tens digit 409 7
Units digit 410 13
A Medical Report (Contact ID Event Code 100) is
sent to the base station receiver when a user presses
[7] and [9] at the same time. A Medical Alarm is
audible, but you can program the alarm as silent by
selecting Option 4 in Location 493 (refer to Section
18.2 System Options 2 on page 81).
Restore Reports are not sent for this
event.
If Codepad Medical Reports are not
required, program Locations 409 and 410
as 0.
15.19 Codepad Reporting Options
Location
411
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
Location 411 is set by default to report only to
Receiver 1. You can select whether Codepad Alarm
Reports are sent to Receiver 1, Receiver 2, or both,
Receiver 2 only when Receiver 1 fails, or no
reporting.
15.20 System Status – AUX Power
Supply Fail Report
Location
412 to 413
Location Default
Tens digit 412 10
Units digit 413 3
A System Trouble Report (Contact ID Event Code
300) is sent when either the codepad AUX power
supply is blown or the AUX power supply
malfunctions. The system reports the event
approximately 10 sec after the failure.
15.21 System Status – AUX Power
Supply Fail Restore Report
Location
414 to 415
Location Default
Tens digit 414 10
Units digit 415 8
A System Trouble Restore Report (Contact ID Event
Code 300) is sent when the AUX power supply is
reset. The system reports the event approximately 10
sec after power supply is reset.
15.22 System Status – AC Fail Report
Location
416 to 417
Location Default
Tens digit 416 10
Units digit 417 2
An AC Fail Report (Contact ID Event Code 301) is
sent to the base station receiver when the AC
MAINS supply is disconnected for 2 min. If you do
not want an AC Fail Report to be sent until the AC
MAINS supply is disconnected for 1 hour, select
Option 1 in Location 494 (refer to Section 18.3 System
Options 3 on page 81). If you want to ignore AC Fail,
select Option 2 in Location 494.
If AC Fail Reports are not required,
program Locations 416 and 417 as 0.
15.23 System Status – AC Fail Restore
Report
Location
416 to 417
Location Default
Tens digit 416 10
Units digit 417 7
An AC Fail Restore Report is sent when the AC
MAINS supply is connected continuously for longer
than 2 min.
If AC Fail Restore Reports are not
required, program Locations 418 and 419
as 0.