Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 25.0 Programming Sheets EN | 107
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Entry Guard Time for STAY Mode
Location
472 to 473 Refer to page 78
Default
0 0
Location 472 Increments of 1 sec (0 to 15 sec)
Location 473 Increments of 16 sec (0 to 240 sec)
Delay Alarm Reporting Time
Location
474 to 475 Refer to page 78
Default
0 0
Location 474 Increments of 1 sec (0 to 15 sec)
Location 475 Increments of 16 sec (0 to 240 sec)
Sensor Watch Time
Location
476 to 477 Refer to page 66
Default
0 0
Location 476 Increments of days (tens digit)
Location 477 Increments of days (units digit)
Codepad Lockout Time
Location
478 Refer to page 79
Default
0
Location 478 Increments of 10 sec
Siren Run Time
Location
479 Refer to page 79
Default
5
Location 479 Increments of 1 minute
Siren Sound Rate (Slow <- Sound -> Fast)
Location
480 Refer to page 79
Default
7
Auto Arming Pre-Alert Time
Location
481 Refer to page 79
Default
1
Location 481 Increments of 5 min
Auto Arming Time
Location
482 to 485 Refer to page 79
Default
0 0 0 0
Location 482 Hour of the day – tens digit
Location 483 Hour of the day – units digit
Location 484 Minute of the day – tens digit
Location 485 Minute of the day – units digit
Auto Disarming Time
Location
486 to 489 Refer to page 79
Default
0 0 0 0
Location 486 Hour of the day – tens digit
Location 487 Hour of the day – units digit
Location 488 Minute of the day – tens digit
Location 489 Minute of the day – units digit
Kiss-Off Wait Time
Location
490 Refer to page 80
Default
3
Location 490 Increments of 500 ms
Speaker Beep Volume
Location
491 Refer to page 80
Default
13
0 No beeps
15 Loudest beeps
System Options 1
Location
492 Refer to page 80
1 Bosch Security Systems, Inc. smart lockout allowed
2 Horn speaker monitor
4 Strobe indications for radio arm/disarm
8
Assign button 4 on transmitter to operate STAY
Mode 1
System Options 2
Location
493 Refer to page 81
Default
0
1 Codepad Panic to be silent
2 Codepad Fire to be silent
4 Codepad Medical to be silent
8 Access denied (code retries) to be silent
System Options 3
Location
494 Refer to page 81
1 AC fail after 1 hour (disabled – after 2 min)
2 Ignore AC fail
4 Pulse count handover allowed
8 Handover delay to be sequential
System Options 4
Location
495 Refer to page 82
Default
0
1 Panel to power up disarmed (if power reset)
2 Arm/disarm tracking on power up
4 Internal crystal to keep time
8 Night arm station, or RE005 installed
Consumer Options 1
Location
496 Refer to page 82
Default
0
1 Test reports only when armed
2 Test report after siren reset
4 Auto arm in STAY Mode 1
8 STAY indicator to display Day Alarm status
Consumer Options 2
Location
497 Refer to page 83
1 Codepad display extinguishes after 60 sec
2
Single button arming allowed (AWAY/STAY Modes
1 and 2)
4
Single button disarming allowed (STAY Modes 1
and 2)
8 Alarm memory reset on disarm