Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 14
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
3.0 System Operations
This section explains the general operations of the
system: arming and disarming the system in the three
modes, isolating zones, initiating codepad alarms,
and determining a fault.
3.1 Arming the System in AWAY Mode
Arming the system in AWAY Mode is normally
performed when you leave the premises and require
that all zones are activated in a ready state to detect
an intrusion.
There are two different methods to arm the system in
AWAY Mode. You can always use method one.
You can use method two only if Option 2 is enabled
in Location 497 (refer to Section 18.6 Consumer
Options 2 on page 83).
If you must isolate a zone (or zones) before arming
the system in AWAY Mode, refer to Section 3.11
Isolating Zones on page 17.
Single button arming in AWAY Mode
reports as User Code number 16.
To arm the system in AWAY Mode (method one):
Enter your code and press [AWAY].
Two beeps sound, the AWAY indicator lights, and
Exit Time starts.
To arm the system in AWAY Mode (method two):
Select Option 2 in Location 497 to
enable single button arming in AWAY
Mode (refer to Section 18.6 Consumer
Options 2 on page 83).
1. Press and hold [AWAY].
2. When two beeps sound, release the button.
The AWAY indicator lights and Exit Time starts.
If a zone is not sealed at the end of Exit Time, the
zone is automatically isolated and its indicator is lit
on the remote codepad. The zone becomes an active
part of the system again as soon as it is resealed. For
example, if a window is open when Exit Time
expires, the window is not an active part of the
system until it is closed. Opening the window after
Exit Time expires causes an alarm.
Forced Arming
Arming the system when a zone is not sealed is
known as forced arming. Refer to Section 14.3.7 Zone
Options 2 on page 63 to enable forced arming for
each zone.
If the AWAY indicator does not light and a long
beep sounds when you attempt to arm the system in
AWAY Mode, forced arming is not permitted. If this
is the case, you seal all zones or manually isolate
them before you can arm the system.
3.2 Disarming the System from AWAY
Mode
When you enter the premises after the system is
armed in AWAY Mode, you must disarm the system
from AWAY Mode to disable detection devices that
activate the sirens, strobe, and bell outputs.
If there was an alarm prior to disarming the system
from AWAY Mode, a zone indicator flashes,
indicating a previous alarm in that zone.
To disarm the system from AWAY Mode:
1. Enter your code and press [AWAY].
2. Two beeps sound and the AWAY indicator is
extinguished.
3.3 Arming the System in STAY Mode 1
STAY Mode 1 is used when you need to arm the
perimeter and unused areas of the premises to detect
a would-be intruder entering the premises, while at
the same time being able to move freely within an
area that is automatically isolated.
Only the installer can program zones to be
automatically isolated in STAY Mode 1. Refer to
Section 14.3.7 Zone Options 2 on page 63 for more
information on setting zones to be automatically
isolated in STAY Mode 1.
There are two methods to arm your system in STAY
Mode 1. You can always use method one. You can
use method two only if Option 2 is enabled in
Location 497 (refer to Section 18.6 Consumer Options 2
on page 83).
If the system reports to a base station, it sends a
Partial Close Report (Contact ID Event Code 456).
Entry Guard Timer for STAY Mode
When arming the system in STAY Mode 1, an
optional entry timer called Entry Guard Timer for
STAY Mode can be used to delay the sirens, strobe,
and bell outputs if a zone that is not automatically
isolated activates an alarm. Entry Guard Timer for
STAY Mode is the delay time used for all zones,
except 24-Hour zones, when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer for STAY Mode is
programmed and a zone that was not automatically
isolated is activated, the codepad beeps twice per sec
until the Entry Guard Timer for STAY Mode expires
or the system is disarmed. If the alarm is not reset
before Entry Guard Timer for STAY Mode expires,
the strobe, bell, and siren outputs are activated into
alarm.
Single button arming in STAY Mode 1
reports as User Code number 16.