Bosch Appliances ICP-CC488 Home Security System User Manual


 
ICP-CC488 | Installation Guide | 3.0 System Operations EN | 17
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
3.9 Codepad Fire Alarm
An audible codepad Fire Alarm activates when a
user presses [4] and [6] on the remote codepad
simultaneously. A distinct fire sound emits through
the horn speaker to indicate this type of alarm. The
fire sound is different than the burglary sound.
Select Option 2 in Location 493 to program the
codepad Fire Alarm as silent (refer to Section 18.2
System Options 2 on page 81). To disable the codepad
Fire Alarm Report, program Locations 407 and 408
to 0 (refer to Section 15.17 Codepad Fire Report). A
codepad Fire Alarm transmits a Contact ID Event
Code 110 to a base station receiver.
3.10 Codepad Medical Alarm
An audible codepad Medical Alarm activates when a
user presses [7] and [9] simultaneously.
Select Option 4 in Location 493 to program codepad
Medical Alarm as silent (refer to Section 18.2 System
Options 2 on page 81). To disable reporting of the
codepad Medical Alarm Report, program Locations
409 and 410 to 0 (refer to Section 15.18 Codepad
Medical Report). A codepad Medical Alarm transmits a
Contact ID Event Code 100 to a base station
receiver.
3.11 Isolating Zones
Isolating zones allows you to manually disable one or
more zones before arming the system in AWAY
Mode, STAY Mode 1, or STAY Mode 2. When a
zone is isolated, access is allowed into that zone when
the system is armed without activating an alarm.
For example, you might want to isolate a zone before
arming the system because a zone passive infrared
(PIR) detector is activating false alarms or because
you need to leave a pet inside a particular zone while
you are away.
You can isolate zones using one of two methods. One
method requires a valid User Code and the other
does not. The ability to isolate zones is determined
by the priority level assigned to each User Code
holder. Some User Code holders cannot isolate
zones. Refer to Section 13.3 User Code Priority for more
information. By default, the standard isolation
method is used.
Zones that are manually isolated using this method
transmit a Zone Bypass Report (Contact ID Event
Code 570) for each isolated zone when the system is
armed. A Zone Bypass Restore Report is transmitted
when the system is disarmed.
When you select a 24-Hour Burglary Zone to be
isolated, a Contact ID Event Code 572 is sent. If you
select a 24-Hour Fire Zone to be isolated, a Contact
ID Event Code 571 is sent.
3.11.1 Standard Isolating
Standard isolating allows any operator to isolate
zones because no code is required.
1. Press [STAY] twice.
Three beeps sound and the STAY indicator
flashes.
2. Enter the number of the zone to be isolated and
press [STAY].
The indicator for the zone flashes.
24-Hour zones are automatically isolated as soon
as you press [STAY]. All other Burglary Zones
are automatically isolated only after the system is
armed.
3. Repeat Step 2 for each zone you want to isolate.
As each zone is selected to be isolated,
the corresponding zone indicator flashes.
If you make a mistake, enter the incorrect
zone number and press [STAY]. This zone
is no longer selected to be isolated and
the zone indicator is extinguished.
4. Press [AWAY].
Two beeps sound and the system returns to the
disarmed state.
The indicators for the selected zones continue to
flash until the next time the system is disarmed.
Example
To manually isolate zones 1, 3, and 4, press:
[STAY][STAY][1][STAY][3][STAY][4][STAY]
[AWAY]
3.11.2 Code to Isolate
The code to isolate method permits only those User
Code holders with a priority level that includes Code
to Isolate. The standard isolating method is disabled
for any User Code with this priority level set.
1. Press [STAY].
2. Enter your code and press [STAY].
Three beeps sound and the STAY indicator
flashes.
If you attempt to enter isolating mode with a
User Code that is not set for Code to Isolate, the
system ignores the attempt.
3. Enter the number of the zone to be isolated and
press [STAY].
The indicator for the zone flashes.
24-Hour zones are automatically isolated as soon
you press [STAY]. All other Burglary zones are
automatically isolated only after the system is
armed.
4. Repeat Step 3 for each zone you want to isolate.
As each zone is selected to be isolated,
the corresponding zone indicator flashes.
If you make a mistake, enter the incorrect
zone number and press [STAY]. This zone
is no longer selected to be isolated and
the zone indicator is extinguished.