3.0 INSTALLATION
The matrix bay communicates with the Controller via RS-422 communications and
therefore can be installed up to 4,000 feet (1,219.2 meters) away from the Control-
ler. Determine where the matrix bay is to be located and follow the mounting and
wiring instructions below.
3.1 MOUNTING INSTRUCTIONS
The matrix bay mounts in a 19-inch rack using standard mounting hardware and
occupies 6 RU (10.5 inches) of vertical space. Place the matrix bay in the desired
location and secure properly.
The matrix bay is designed for low power consumption and therefore has no internal
fans. If mounting several matrix bays together in the same location or if installing in
high temperature environments, it is highly recommended that you separate the
units by at least 1 RU (1.75 inches). In high temperature environments, it also may
be necessary to provide forced air cooling. Contact Pelco for additional information.
Once the unit has been secured into the equipment rack, remove the front panel of
the unit to gain access to the circuit cards. Ensure each card is firmly seated in the
frame.
NOTE:
Make sure the selected lo-
cation has adequate power available.
The unit operates on either 120 VAC
or 230 VAC input power.
Figure 23. Mounting the Matrix Bay