Honeywell THX9321 Thermostat User Manual


 
THX9321 PRESTIGE
®
2.0 AND THX9421 PRESTIGE
®
IAQ 2.0 WITH EIM
68-0311—01 4
Thermostat Description:
Electrical Ratings:
Power Consumption of THX9421/THX9321:
Full brightness = 3.0 VA
1/2 brightness = 2.1 VA
Backlight off = 1.9 VA
Operating Ambient Temperature:
THX9421/THX9321: 32 to 120 °F (0 to 48.9 °C)
THM5421R1013: -40 to 165 °F (-40 to 73.9 °C)
THM6000R1002: 32 to 120 °F (0 to 48.9 °C)
REM5000R1001: 32 to 120 °F (0 to 48.9 °C)
REM1000R1003: 32 to 120 °F (0 to 48.9 °C)
HVC20A1000: 32 to 120 °F (0 to 48.9 °C)
C7089R1013: -40 to 140 °F (-40 to 60 °C)
C7089U1006: -40 to 120 °F (-40 to 48.9 °C)
C7189R1004: 0 to 120 °F (-17.8 to 48.9 °C)
For Optimal Battery Life: 35 to 114 °F (1.7 to 45.6 °C)
C7189U1005: 45 to 88 °F (7 to 32 °C)
C7772A1004: 45 to 99 °F (7 to 37 °C)
C7772A1012: 45 to 99 °F (7 to 37 °C)
TR21: 45 to 99 °F (7 to 37 °C)
TR21-A: 45 to 99 °F (7 to 37 °C)
C7735A1000: 0 to 200 °F (-17.8 to 93.3 °C)
C7041:
C7770A1006: 45 to 99 °F (7 to 37 °C)
THP1000A1007: 0 to 130 °F (-17.8 to 54.4 °C)
THP9045A1023: -40 to 163 °F (-40 to 73 °C)
Shipping Temperature:
THX9421/THX9321: -20 to 120 °F (-28.9 to 48.9 °C)
THM5421R1013: -20 to 165 °F (-28.9 to 73.9 °C)
THM6000R1002: -20 to 120 °F (-28.9 to 48.9 °C)
REM5000R1001: -20 to 120 °F (-28.9 to 48.9 °C)
REM1000R1003: -20 to 120 °F (-28.9 to 48.9 °C)
HVC20A1000: -20 to 120 °F (-28.9 to 48.9 °C)
C7089R1013: -40 to 120 °F (-40 to 48.9 °C)
C7089U1006: -40 to 130 °F (-40 to 54.4 °C)
C7189R1004: -20 to 120 °F (-28.9 to 48.9 °C)
C7189U1005: -20 to 120 °F (-28.9 to 48.9 °C)
C7772A1004: -40 to 150 °F (-40 to 65.5 °C)
C7772A1012: -40 to 150 °F (-40 to 65.5 °C)
TR21: -40 to 150 °F (-40 to 65.5 °C)
TR21-A: -40 to 150 °F (-40 to 65.5 °C)
C7735A1000: -20 to 120 °F (-28.9 to 48.9 °C)
C7041:
C7770A1006: -40 to 150 °F (-40 to 65.5 °C)
THP1000A1007: 0 to 130 °F (-17.8 to 54.4 °C)
THP9045A1023: -40 to 185 °F (-40 to 85 °C)
Operating Relative Humidity:
THX9421/THX9321: 5 to 90% non-condensing
THM5421R1013: 5 to 95% non-condensing
THM6000R1002: 5 to 90% non-condensing
REM5000R1001: 5 to 90% non-condensing
REM1000R1003: 5 to 90% non-condensing
HVC20A1000: 5 to 90% non-condensing
C7089R1013: 0 to 100% condensing
C7089U1006: 5 to 95% non-condensing
C7189R1004: 5 to 90% non-condensing
C7189U1005: 5 to 95% non-condensing
C7772A1004: 5 to 95% non-condensing
C7772A1012: 5 to 95% non-condensing
TR21: 5 to 95% non-condensing
TR21-A: 5 to 95% non-condensing
C7770A1006: 5 to 95% non-condensing
THP1000A1007: 5 to 90% non-condensing
THP9045A1023: 5 to 90% non-condensing
Temperature Setting Range:
Heating: 40 to 90 °F (4.5 to 32 °C).
Cooling: 50 to 99 °F (10 to 37 °C).
Humidification Setting Range:
10% to 60% RH.
Dehumidification Setting Range:
40% to 80% RH.
Humidity Display Range:
0% to 99%.
Cool Indication:
Prestige 2.0 and Prestige IAQ 2.0 displays “Cool On” when the
thermostat turns the cooling on.
Heat Indication:
Prestige 2.0 and Prestige IAQ 2.0 displays “Heat On” when the
thermostat turns the heating on.
Auxiliary Heat Indication:
Prestige 2.0 and Prestige IAQ 2.0 displays “Auxiliary Heat On”
when the thermostat turns the auxiliary heat on.
Interstage Differential:
Comfort: The thermostat keeps the indoor temperature within 1
degree of the setpoint (droop less control). The thermostat
turns on stage 2 when the capacity on stage 1 reaches
90%.
When the interstage differential is set to 1.0 or higher, the ther-
mostat stages the equipment based on how far the indoor
temperature is from the setpoint (ISU 3030 to 3090). See
page 21 for more information.
Feature Description
Powering method Common wire only
System types (up to
4 heat/2 cool heat
pump and up to 3
heat/2 cool
conventional)
Gas, oil or electric heat with air
conditioning
Warm air, hot water, high-efficiency
furnaces, heat pumps, steam and
gravity
Cool only
Changeover Manual or Auto changeover selectable
System setting Em Heat-Heat-Off-Cool-Auto
Fan setting Auto-On-Circ-Follow Schedule
Terminal
Voltage
(50/60 Hz)
Max. Current
Rating
W - O/B 18 to 30 VAC and
750 mVDC
1.00A
Y (cooling) 18 to 30 VAC 1.00A
G (fan) 18 to 30 VAC 0.50A
W2 - Aux 1 (heating) 18 to 30 VAC 0.60A
Y2 (cooling) 18 to 30 VAC 0.60A
W3 - Aux 2 18 to 30 VAC 1.00A
A-L/A (Output) 18 to 30 VAC 1.00A
U1, U1 18 to 30 VAC 0.50A
U2, U2 18 to 30 VAC 0.50A
U3, U3 18 to 30 VAC 0.50A