Security (cont'd)
15
U
L
CO annunciation has not been investigated by UL and may not be used for UL installations.
In Case of Fire Alarm
1. A FIRE message appears at your keypad and remains on until you silence the alarm.
2. Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad and
manually initiate an alarm by pressing the panic key assigned as FIRE emergency (if programmed by the installer) and hold
down for at least 2 seconds.
3. Evacuate all occupants from the premises.
4. If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately.
Silencing and Clearing a Fire/Carbon Monoxide Alarm
1. Silence, acknowledge, and clear the alarm by:
a. For Residential Systems: Press “Touch here to Silence” on the display to silence the alarm.
For Commercial Systems: Enter your code. This silences and acknowledges the alarm and disarming of the system (if
armed).
b. For Residential Systems: Press the CLEAR icon followed by your code. This acknowledges the alarm and the
disarming of the system (if armed).
For Commercial Systems: Press the CLEAR icon followed by your code. The system attempts to clear the alarm from
memory. If NOT successful (i.e., smoke in the detector) the Security screen is displayed and the Display Faults icon
displays a “Not Ready Fault”.
c. Press the DISPLAY FAULTS icon on the Arming screen. The faulted fire/carbon monoxide zone is displayed.
d. Press the CLEAR icon and then enter your code. This clears the Fire Alarm/CO Alarm from the system.
2. If the keypad does not indicate a READY condition after the second sequence, press the DISPLAY FAULTS key on the
Arming screen to display the zone(s) that are faulted. Be sure to check that smoke detectors/carbon monoxide detectors are
not responding to smoke, heat, or gas producing objects in their vicinity. In this case, eliminate the source of heat, smoke or
leak.
3. If this does not remedy the problem, there may still be smoke/gas in the detector. Clear it by fanning the detector for about
30 seconds.
4. When the problem has been corrected, clear the display by entering the DISPLAY FAULTS icon on the Arming screen,
selecting the fire or carbon monoxide zone, pressing the CLEAR icon and then entering your user code.
Note: Contact your Central Station/Security Company for servicing if you have further problems with your system.