Configuring via WIN-PAK
Adding a New NetAXS™ Panel
The NetAXS™ Gateway panel’s baud rate is set configured via the NetAXS™ web server (see
the NetAXS™ Access Control Unit Installation Guide for instructions). When you set the Loop
Type in the QSW to 485 ACK-NAK, you define the baud rate to be 19.2 kilobits per second.
This baud rate and the panel’s baud rate must match to communicate properly. For WIN-PAK
SE or WIN-PAK PE systems, you can adjust the baud rate of the N-485 device to 115 kilobits
per second for optimum performance.
3.2 Adding a New NetAXS™ Panel
To add a NetAXS™ panel, first create the panel in the WIN-PAK Quick Start Wizard, and then
complete the configuration manually with the WIN-PAK Panel Configuration screen.
3.2.1 Creating the Panel with Quick Start Wizard
Add a new panel by selecting its Loop and configuring the following from the Quick Start Wizard
Panel screen:
Panel type (Select N1000-4X/PW2000-4X from the dropdown list)
Panel name (Loop[Loop number]-Panel [Panel address]
Panel address (Select from the dropdown list)
Figure 3-1: Quick Start Wizard - Panel Screen
Note: Each panel on a communication loop must have a unique address. The address must correspond
with the address that is set by DIP switches on the panel.
After adding the NetAXS™ panel via the QSW, you must update the Reader and Input interlocks to
match them with the default wiring of the NetAXS™ panel. Proceed to “Configuring the Panel
Manually“ on page 67 and make the necessary changes.