58 www.honeywell.com
Configuring via the Web Server
Configuring the System
Steps: Use the descriptions in the following table to configure each group:
Table 2-12: Configuration > Other I/O & Groups > Groups Tab Field Descriptions
Setting Description
Name Enter a unique name to identify the group.
Pulse Time Specifies the duration for which the device will assume
abnormal status. For example, it specifies how long a horn will
blow or a door strike will remain released. The maximum
number of hours is 1. When the hour field is blank, the
maximum number of minutes is 59. When 1 is entered in the
hour field, the maximum number of minutes is 45. The sum of
all three units comprises the pulse time. Note that you can
express seconds in tenths of a second.
Energized TZ Specifies the period during which the group of output relays are
automatically energized.
Interlock Disabled
TZ
Specifies the period during which the interlocks that control the
group’s outputs will be disabled.
Latch Toggles the state of the outputs between energized and
de-energized status upon every activation (code use, interlock,
or manual pulse).