Honeywell 800-04410 Home Security System User Manual


 
56 www.honeywell.com
Configuring via the Web Server
Configuring the System
Steps: Use the descriptions in the following table to configure each output device:
Table 2-11: Configuration > Other I/O & Groups > Outputs Tab > Fields
Setting Description
Name Enter a unique name to identify the device.
Pulse Time Specifies the duration for which the device will assume
abnormal status. For example, it specifies how long a horn will
sound or a door strike will remain released. The maximum
number of hours is 1. When the hour field is blank, the
maximum number of minutes is 59. When 1 is entered in the
hour field, the maximum number of minutes is 45. The sum of
all three units comprises the pulse time. Note that you can
express seconds in tenths of a second.
Time Zones Defines the period of time during which inputs, outputs, groups,
readers, access levels, and cards will either be energized or
de-energized, enabled or disabled.
Latching When selected, this toggles a relay with either a valid card,
interlock, or manual pulse.
Interlock Enables you to disable the interlock, or programmed interaction
between two points.