Bradford-White Corp 238-47878-00B 04/10 Water Heater User Manual


 
Remote Mounting the Setback Control
-61-
Install Wire (C) – Backplate
Step 11: Using wire (C), insert one end into the bottom terminal location on the backplate (located on
the Setback Control Junction Box Assembly). This is shown in Figure 92. Be sure that the wire already
located in this location is not dislodged.
Fasten Wire (C) into its Designated Location – Backplate
Step 12: Tighten the slotted screw in the bottom terminal location on the backplate (located on the
Setback Control Junction Box Assembly). This is shown in Figure 93.
Figure 93
Figure 92
Wires Already
Installed
Wire (A) Wire (B)
Backplate
Wire (C)
Wire (A)
Slotted head
screwdriver
Backplate
Setback Control
Junction Box Assembly
Wire (B)
Wire (C)