Bradford-White Corp 238-47878-00B 04/10 Water Heater User Manual


 
Remote Mounting the Setback Control
-57-
Mount the Protective Plate
Step 3: Mount the Setback Control Protective Plate in a desired location. Be sure that the Setback
Control will not be direct sunlight, as the display may be difficult to read. This is shown in Figure 84.
Measure Wire for Remote Mounting
Step 4: Measure and cut (3) pieces of 18 AWG wire to a sufficient length to reach from the backplate on
the Setback Control Junction Box Assembly to the Setback Control Protective Plate. This is shown in
Figure 85.
Figure 85
Fi
g
ure 84
Drill
Protective
Plate
18 AWG
Wire
Wall