Bosch Appliances D9412GV2 Home Security System User Manual


 
D9412GV2/D7412GV2 | Operation and Installation Guide | 11.0 Arming Devices
56 Bosch Security Systems, Inc. | 5/05 | F01U003641B
Momentary Contact
If the point to which the keyswitch is connected is programmed for a momentary contact, shorting the arming
circuit toggles the area’s arming state between armed and disarmed. All faulted points are force armed, regardless
of the entry in the FA Bypass Max program item. Refer to Point Assignments in the D9412GV2/D7412GV2 Program
Entry Guide (P/N: F01U003636).
Silencing the Bell
To silence the bell (stop Alarm Bell output) if the system is armed, position the keyswitch to disarm the area. If the
area is disarmed, turn the keyswitch once to start the arming process. Turning the keyswitch a second time stops
the arming process and silences the bell.