V
7
(2) Outdoor unit
1) If there is no obstacle around the outdoor unit...
2) If there is an obstacle around the outdoor unit...
◆ If an obstacle in front of the outdoor unit is higher than
1500mm, the half of additional height should be added to
the S1.
◆ If an obstacle behind the outdoor unit is higher than
500mm, the half of additional height should be added to
the S2.
S1 S2
Unit : mm
1500
h1
500
h2
Air inlet
Front
❋ Max. height of obstacle
- Front side : 1500mm or less
- Air inlet side : 500mm or less
- Right/Left side : No limit
100 or more
100 or
more
100 or
more
300 or more
Front
500
or more
Front
300 or more
500 or
more
100 or
more
100 or
more
100 or
more
100 or more
100 or
more
300 or more
Front
500
or more
Front
100 or more
500 or
more
200 or
more
200 or
more
100 or
more
100 or
more
Unit : mm