Parker Hannifin 88-021610-01G Home Security System User Manual


 
Parker Hannifin
194 Aries User Guide
remove the paint in certain areas to ensure filters and drive make a
good large-area metal to metal contact between filter case and
panel.
You must install a filter on both the Motor power mains and Control
power mains if both are used. Use Table 60 and Table 61 to determine
the corre
ct filter for your specific application.
Control Power
Control power is 1 Amp, maximum. Any of the following filters works with all
models of the drive.
Filter Manufacturer
6EP1 (160937-5) Corcom
10EP1 (160937-7)
1,
Corcom
FN2070-10/06 Schaffner
1. Available from Parker: 10 Amp filter—part number 47-016140-01
16 Amp filter—part number 47-017900-01
Table 60 Control Power Filter Selection
Mains Motor Power
Filter Continuous
Current
(Amps)
AR-
01xx
AR-
02xx
AR-
04xx
AR-
08xx
AR-
13xx
AR-
20xE
AR-
30xE
6EP1 (160937-5)
1
5 at 240 VAC
× ×
10EP1 (160937-7)
1, 3
8 at 240 VAC
× × × ×
x
FN2070-10/06
2
10 at 240 VAC
× × × ×
x
FN2070-12/06 12 at 240 VAC
× × × ×
x
FN2070-16/06
2, 3
16 at 240 VAC
× ×
x
16FCD10
1
16 at 240 VAC x
25FCD10
1
25 at 240 VAC x x
Product with applicable mains filter denoted by “×
1. Corcom (a division of Tyco Electronics)
2. Schaffner
3. Available from Parker: 10 Amp filter—part number 47-016140-01
16 Amp filter—part number 47-017900-01
Table 61 Mains Motor Power Filter Selection
Install Transient suppressors
.
Single Phase Input
You must install varistors or other voltage surge limiting devices in order
to meet the requirements of EN61000-4-5. Place a Littelfuse
V275LA2ØC, or an equivalent varistor, from line to line and from lines to
earth before the mains filter, as shown in the EMC Installation drawings.
(Intersil, General Electric, and Littelfuse manufacture equivalent
varistors.)