Chapter 7 Troubleshooting 167
Phase Hall State
U V W Correct
Use SHALL1
+ 1 6
+ + 5 2
+ 4 3
+ + 6 1
+ 2 5
+ + 3 4
Table 51 Configuring Hall Sensors
Figure 50 illustrates the alignment of phase
s U, V, and W with Halls 1, 2, and
3 as viewed from the front of the shaft. The illustration assumes the following:
Hall signals that are High equal
TRUE signals.
Hall 1 is the least significant bit (LSB).
Hall 3 is the most significant bit (MSB).
There is one hall cycle and one electrical cycle per pole pair on the
motor.
Figure 50 Motor Terminal Voltages (back EMF) and Hall Sensor Signals