918
FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
B Instruction Execution Time
B-1 Basic Instruction Execution Time
Output instructions
OUT Y,M 0.21 1.2 µs in 2-step instruction
OUT S 1.25 1.25
OUT T K 2.41 2.16
OUT T D 2.77 2.54
OUT C K 1.9 2.25 1.57 1.72
C235 to C255
1.6 µs in execution in ON status
1.06 µs in execution in OFF status
OUT C D 2.26 1.49 1.93 2.35
C235 to C255
2.21 µs in execution in ON status
1.06 µs in execution in OFF status
SET Y,M 0.23 1.25 µs in 2-step instruction
SET S 1.23 or 1.33 + 0.51n 0.59
n: Number of recombination
1.23 µs when there is no recombination
RST Y,M 0.23 1.22 µs in 2-step instruction
RST S 1.17 0.59
RST T 1.68 1.21
RST C 1.77 1.82 1.18 1.19
RST D 1.08 0.54
PLS Y,M 1.52
PLF Y,M 1.52
Master control instructions
MC 1.63 1.76
MCR 1.3 ⎯
Other instruction
NOP 0.21
End instruction
END 209 ⎯
Even if FEND and END are used
together, execution time of only END is
required.
Instruction
Execution time in ON status (µs) Execution time in OFF status (µs)
Remarks
16-bit instruction 32-bit instruction 16-bit instruction 32-bit instruction