FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
13 High-Speed Processing – FNC 50 to FNC 59
13.10 FNC 59 – PLSR / Acceleration/Deceleration Setup
3. Handling of pulse output terminals in FX3S/FX3G/FX3GC/FX3U/FX3UC series main units
The outputs Y000 and Y001 are the high-speed response type.
When using a pulse output instruction or positioning instruction, adjust the load current of the open collector transistor
output to about 10 to 100 mA (5 to 24V DC).
When the load is smaller, connect a dummy resistor in parallel to the outside of a used output terminal (Y000 or Y001)
as shown in the circuit diagram below so that the specified current shown above flows in the output transistor.
4. Cautions on special high-speed output adapters
1) Outputs of special high-speed output adapters work as differential line drivers.
2) Set the pulse output type setting switch in a special high-speed output adapter to the "pulse chain + direction"
(PLSDIR) side.
If the switch is set to the "forward rotation pulse chain reverse rotation pulse chain" (FPRP) side, normal
operations are disabled. The pulse output destination changes depending on the PLC output status as shown in
the table below.
3) Set the pulse output type setting switch while the PLC is stopped or while the power is OFF.
Do not manipulate the pulse output type setting switch while pulses are being output.
4) When special high-speed output adapters are connected, the same output numbers in the main unit are assigned
as shown in the table below.
Only wire the appropriate output terminals.
Outputs in special high-speed output adapters and the main unit operate as shown below.
Assignment of output numbers in special high-speed output adapter
Output operation
Item Description
Operating voltage range 5 to 24V DC
Operating current range 10 to 100 mA
Output frequency 100 kHz or less
Pulse output
destination
Output affecting
operation
Operation
= Y000
Y004
While Y004 is ON, pulses are output from Y000 in the high-speed output adapter.
While Y004 is OFF, pulses are output from Y004 in the high-speed output adapter.
= Y001
Y005
While Y005 is ON, pulses are output from Y001 in the high-speed output adapter.
While Y005 is OFF, pulses are output from Y005 in the high-speed output adapter.
Setting status of output form
setting switch
Signal name
Setting name in each
positioning instruction
Output number
1st unit 2nd unit
1st axis 2nd axis 3rd axis 4th axis
"FPRP" side
Forward rotation pulse
chain (FP)
Pulse output destination Y000 Y001 Y002 Y003
Reverse rotation pulse
chain (RP)
Rotation direction signal Y004 Y005 Y006 Y007
"PLSDIR" side
Pulse chain Pulse output destination Y000 Y001 Y002 Y003
Direction Rotation direction signal Y004 Y005 Y006 Y007
Output operation
Relay output type/triac output type main
unit
While instruction is active, associated output is ON. (LED is also ON.)
Use a special high-speed adapter.
Special high-speed output adapter
Operated. (LED is also operated.)
Set the output frequency to "200kHz" or less.
Transistor output type main unit
Operated. (LED is ON.)
Set the output frequency to "100kHz" or less.
External
power
supply
Equipment
load
resistor
Dummy
resistor
Y000
COM1
PLC
(transistor output)
[sink output]
D
D