32.1 FNC280 – HSCT / High-Speed Counter Compare With Data Table
Outline
This instruction compares the current value of a high-speed counter with a data table of comparison points, and then
sets or resets up to 16 output devices.
1. Instruction format
2. Set data
3. Applicable devices
Only a high-speed counter C235 to C255 can be specified in "S".
Explanation of function and operation
1. 32-bit operation (DHSCT)
The current value of a high-speed counter specified in is compared with the data table shown below which has
(3m) points stored in and later, and the operation output set value (ON or OFF) specified in the data table is
output to to +n-1.
Data table used for comparison
Operand Type Description Data Type
Head device number storing the data table 16- or 32-bit binary
m Number of comparison points in data table [1m128] 16-bit binary
High-speed counter number (C235 to C255) 32-bit binary
Head device number to which the operation status is output Bit
n Number of devices to which the operation status is output [1n16] 16-bit binary
Oper-
and
Type
Bit Devices Word Devices Others
System User Digit Specification System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
XYMTCSD
.b KnX KnY KnM KnS T C D R
U\G
V Z Modify K H E "
"P

m 
S

n 
Comparison
point number
Comparison value
Operation output set value
(SET [1] or RESET [0])
Operation output destination
0
+1, +2
to +n-1
1
+4, +3 +5
2
+7 +6 +8
...
...
...
m-2
+3m-5, +3m-6 +3m-4
m-1
+3m-2, +3m-3 +3m-1
FNC 280
HSCT
D
Mnemonic Operation Condition
16-bit Instruction
21 steps
DHSCT
Mnemonic Operation Condition
Continuous
Operation
32-bit Instruction
S
1
S
2
D
S
1
S
2
D
S
2
S
1
D
D
FNC280
DHSCT
S
1
m D
nS
2
Command
input
S
1
S
1
S
1
D D
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1
S
1