FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
35 SFC Program and Step Ladder
35.1 SFC Program
31
FNC277-FNC279
Data
Transfer 3
32
FNC280-FNC289
High-Speed
Processing 2
33
FNC290-FNC299
Extension File
Register Control
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
Examples of flows having selective branches and recombination
1. Operation of selective branch
• When two or more flows are provided and
either one is selected and executed, it is
called a selective branch.
• In the example shown on the right, X000,
X010 and X020 should not turn ON at the
same time.
• For example, when X000 turns ON while
S20 is ON, the ON status is transferred to
S21; S20 turns OFF, and S21 turns ON.
Accordingly, even if X010 or X020 turns
ON after that, S31 and S41 do not turn ON.
• The recombination state relay S50 is
driven by either S22, S32 or S42.
2. Example of selecting and carrying large and small balls
The figure below shows a mechanism which selects and carries large and small balls using conveyors.
The upper left position is regarded as the origin, and the mechanism performs in the order “moving down → suction →
moving up → moving rightward → moving down → release → moving up → moving leftward”.
When the arm moves down and the electromagnet pushes a large ball, the lower limit switch LS2 turns OFF. When the
electromagnet pushes a small ball, LS2 turns ON.
20
1
21
2
22
3
50
4
31
5
32
6
7
8
9
TRAN
X000
TRAN
X002
TRAN
X010
TRAN
X012
41
42
TRAN
X020
TRAN
X022
10
+
M
+
Small Large
X004
LS4
X005
LS5
X001
LS1 Left limit switch
X003
LS3 Upper
limit switch
Origin
indication
Y007
Moving
rightward:
Y003
Moving
leftward:
Y004
Moving up:
Y002
Moving down:
Y000
CY1
X002
LS2 Lower limit switch
When a large ball is pushed, the piston does
not reach the lower limit and X002 does not
turn ON.
Proximity
switch
PS0
X000
Electromagnet
Y001
X026
Start