Programming Manual - Basic & Applied Instruction Edition
21 Real Time Clock Control – FNC160 to FNC169
21.2 FNC161 – TZCP / RTC Data Zone Compare
21
FNC160-FNC169
Real Time Clock
Control
22
FNC170-FNC179
External Device
23
FNC180
Alternate
Instructions
24
FNC181-FNC189
Others
25
FNC190-FNC199
Block Data
Operation
26
FNC200-FNC209
Character String
Control
27
FNC210-FNC219
Data
Operation 3
28
FNC220-FNC249
Data
Comparison
29
FNC250-FNC269
Data Table
Operation
30
FNC270-FNC276
Ex-Device
21.2 FNC161 – TZCP / RTC Data Zone Compare
Outline
This instruction compares two comparison time (comparison time zone) with the time data, and turns ON or OFF the
specified bit devices according to the comparison results.
1. Instruction format
2. Set data
3. Applicable devices
S1: "D.b" is available only in FX3U and FX3UC PLCs. However, index modifiers (V and Z) are not available.
S2: This function is supported only in FX
3G/FX3GC/FX3U/FX3UC PLCs.
S3: This function is supported only in FX
3U/FX3UC PLCs.
Explanation of function and operation
1. 16-bit operation (TZCP)
The lower limit and upper limit comparison time (hour, minute, and second) are compared with the time data (hour,
minute, and second) stored in three devices , +1, and +2. Three devices starting from turn
ON or OFF according to the comparison result.
Operand type Description Data type
Specifies "hour" of the lower limit comparison time (hour, minute, and second).
(Three devices are occupied.)
16-bit binary
Specifies "hour" of the upper limit comparison time (hour, minute, and second).
(Three devices are occupied.)
16-bit binary
Specifies "hour" of the time data (hour, minute, and second).
(Three devices are occupied.)
16-bit binary
Turns ON or OFF according to the comparison result.
(Three devices are occupied.)
Bit
Oper-
and
Type
Bit Devices Word Devices Others
System User Digit Specification System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
XYMTCSD
.b KnX KnY KnM KnS T C D R
U\G
V Z Modify K H E "
"P
S2 S3
S2 S3
S2 S3
 S1
P
FNC 161
TZCP
Mnemonic Operation Condition
16-bit Instruction
9 steps
TZCP
TZCPP
Mnemonic Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
S
1
S
1
S
2
S
D
S
1
S
1
S
2
S
S
2
D
S
S
S
D
Turns ON in the case of " ".
Turns ON in the case of " ".
Turns ON in the case of " ".
Command
input
FNC161
TZCP
S
1
S
2
S D
>
This instruction compares the
comparison time zone specified by two
points with the time data.
S
+1 (minute)
(hour)
+2 (second)
S
S
S
+1 (minute)
(hour)
+2 (second)
S
S
S
+1 (minute)
(hour)
+2 (second)
S
S
S
1
+1 (minute)
(hour)
+2 (second)
S
1
S
1
S
1
+1 (minute)
(hour)
+2 (second)
S
1
S
1
S
2
+1 (minute)
(hour)
+2 (second)
S
2
S
2
S
2
+1 (minute)
(hour)
+2 (second)
S
2
S
2
≤≤
>
D
+1
D
+2
D
Even if the command contact turns OFF from ON and TZCP instruction is not executed, ,
+1 and +2 hold the status before the command contact turned OFF.
D
D D