39
T
ROUBLESHOOTING
10. Short the A IN- terminal screw to the COMMON terminal screw with a
short piece of wire. The red A IN LED should light and the scanner
should emit a repetitive warning tone as long as this connection is
maintained.
11. Disconnect then reconnect power to the scanner. Enter scanner
program mode by choosing Enter Program Mode from the HoloSet
Main Menu. (Do not try to use the HoloSet bar code label at this time)
DISABLE all TECH options then re-program the scanner. This
neutralizes the test program disabling the unconnected sensor inputs
and turns the TRIAC output off.
12. If needed, the scanner can now be programmed for your particular
application.