7
C
ONFIGURING THE
MX001
FOR
115
OR
230
V
OLT
O
PERATION
Europe/Asia: 230V Operation
1. Move the voltage selector to the left with a small screwdriver so that the
230V legend shows in the window.
2. Open the fuse kit and remove the following:
• (2) Black Fuse Holder Caps
• (1) 6.3 Amp 250V Fast Acting, High Interrupt 5 x 20 mm Fuse
• (1) 50ma 250V Time Delay 5 x 20 mm Fuse
3. Press the end of the 6.3 Amp fuse into one of the black fuse holder caps
until it seats.
4. Insert the fuse and cap into the F1 TRIAC fuse holder with the screwdriver
slot pointing toward the power transformer.
5. Using a small screwdriver, press the cap down into the fuse holder body and
turn the cap ¼ turn clockwise to lock the cap in place. This results in the cap
slot pointing toward the top and bottom of the box.
6. Press the end of the 50mA fuse into the other black fuse holder cap until it
seats.
7. Insert the fuse and cap into the F2 control fuse holder with the screwdriver
slot pointing toward the power transformer.
8. Using a small screwdriver, press the cap down into the fuse holder body and
turn the cap ¼ turn clockwise to lock the cap in place. This results in the cap
slot pointing toward the top and bottom of the box.