Low Voltage Self-Contained DC sensors with a Current Sourcing
Output
1. Make sure power is not being applied to the unit.
2. Open the terminals
in the sensor terminal block by turning each screw
counterclockwise until there is enough space to insert wires.
3. Strip off 2 ¼ inches of the sensor cable’s outer jacket.
4. Strip insulation off each cable wire ¼ of an inch.
5. Feed the sensor cable through the small strain relief.
6. Connect a small jumper wire between the COMMON and the S IN-
terminals. Secure the jumper wire in the S IN- terminal by turning the
terminal’s screw clockwise. (Refer to the MX001 box or to Figure 12 for the
order of the terminals for the sensor wires.
7. Connect the sensor’s DC common wire to the COMMON terminal and
secure the sensor and jumper wire by turning the terminal’s screw
clockwise.
8. Insert and secure the sensor’s +DC power input wire into the +12V OUT
terminal.
9. Insert and secure the sensor’s sourcing output wire into the
S IN+ terminal.
10. Secure the cable by turning the strain relief’s domed sealing nut clockwise
until tight.
11. Position the jumper on pins 1 and 2 of the J1 (S SET UP) header. (Refer to
Figure 13).