Brother BES-962BC Sewing Machine User Manual


 
Chapter 2 Preparation of Embroidery Machine
BES-962BC BES-1262BC
40
4. Connect the interface board female connector and the control box connector SBUS1 of the
first machine using an IF cable.
5. Connect the control box connector SBUS2 of the first machine and the control box connector
SBUS1 of the second machine using an IF cable.
6. Connect the control box connector SBUS2 of the second machine and the control box
connector SBUS1 of the third machine using an IF cable.
7. Connect the control box connector SBUS2 of the third machine and the control box connector
SBUS1 of the forth machine using an IF cable.
8. Attach a terminator to the control box connector SBUS2 of the forth (last) machine.
* The IF cables used for connection are identical. There is no difference between the two ends
of the IF cable.
* The order of connecting four machines is arbitrary.
* The maximum number of connecting machines is four.
* A terminator should be connected to the connector SBUS2 of the lastly connected machine.
Connection to SBUS1, 2 can be interchangeable.
* Do not connect anything to the RS-232C connector.
Optional paper tape reader cannot be connected to this connector.
(Terminator)