Brother BES-962BC Sewing Machine User Manual


 
Chapter 11 Error code list
BES-962BC BES-1262BC
249
Code
E-C3
E-C4
E-C5
E-C6
E-C7
E-C8
E-C9
E-CA
E-CB
E-CC
E-CD
E-CE
E-CF
E-D0
E-D1
E-D2
E-D3
E-E1
E-E2
E-E3
E-E4
E-E5
E-E6
E-E7
E-E8
Error
Embroidering data buffer empty
Presser foot down error
Measured voltage value could not be received form
the lower shaft motor CPU.
Voltage value could not be transferred to the lower
shaft motor CPU.
Lower shaft error
Hook motor origin point error
Embroidering start error
No sewing permission is given from PC.
Spindle rotation speed error
Shuttle thread entanglement automatic reset
Speed command can not be received.
Cylinder bed position error
Rated voltage value could not be received from the
lower shaft motor CPU.
Power PC board error
Cooling fan motor stop B Tum the power off.
Power voltage upper limit error
Power voltage lower limit error
X-axis pulse motor overcurrent stop
Y-axis pulse motor overcurrent stop
Cooling fan motor stop A Press R.
Lower shaft communication error
Over-run error during interfacing to main PCB CPU
Framing error during interfacing to main PCB CPU
Parity error during interfacing to main PCB CPU
Receiving time up error during interfacing to main
PCB CPU
Measures
Is the IF cable disconnected? If it is connected normally, the cable or the
main board is faulty.
Press the
STOP
or turn on the F/B switch on the head to either side. If the
same error occurs again, adjust the presser foot switch.
This is not usually displayed.
The machine may be being tested in the BC test mode. Exit the test mode
or turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
Check the operation of the main shaft brake and the stop position of the
main shaft (100 degrees).
The is pressed while no sewing data has been transferred to the em-
broidery machine. Clear this error by the
STOP
. To start sewing, transfer
necessary data from the machine controller and press the .
This is not usually displayed.
Press the
STOP
or turn on the F/B switch on the head to either side to cancel
the error and press the . If the same error occurs again, there is a
possibility that the spindle is overloaded.
This is not usually displayed.
Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
Secure the bed. If the bed is secured, the bed sensor position may be
faulty. Readjust it.
Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
Turn the power off and on once. If the same error occurs again, the power
PCB is faulty.
Turn off the power and check the fan harness. Turn on the power again. If
the same error occurs again, the fan or the power PCB is faulty.
(1) The voltage setting is improper. -> Set it again.
(2) Press the
STOP
or turn on the F/B switch on the head to either side. If
the same error occurs again, the power PCB or the power supply is
faulty.
Turn the power off and on once.
Turn off the power and check the fan harness. Turn on the power again. If
the same error occurs again, the fan or the power PCB is faulty.
Turn the power off and on once. If the same error occurs again, the main
PCB is faulty.
This is not usually displayed.